Skip to main content

ADVERTISEMENT

Jerôme Wintzer-Wehekind, MD

Characteristics and Outcomes of Patients Who Are Denied From a Percutaneous Edge-to-Edge Mitral Valve Repair After Being Referred to a Transcatheter Mitral Valve Program: Impact of a Dedicated Multidisciplinary Mitral Heart Team Approach
Original Contribution
05/30/2020
Abstract: Background. Many patients referred for a MitraClip intervention are finally refused for this intervention, and data are very scarce on their outcomes. Our study sought to determine the characteristics and outcomes of patients who...
Abstract: Background. Many patients referred for a MitraClip intervention are finally refused for this intervention, and data are very scarce on their outcomes. Our study sought to determine the characteristics and outcomes of patients who...
Abstract: Background. Many...
05/30/2020
Journal of Invasive Cardiology
Interaction Between Balloon-Expandable Valves and Coronary Ostia: Angiographic Analysis and Impact on Coronary Access
Original Contribution
05/20/2020
We sought to evaluate the position of balloon-expandable valves in relation to the coronary ostia using an angiographic- and computed tomography (CT)-based analysis, and to determine the impact of valve position on coronary angiography...
We sought to evaluate the position of balloon-expandable valves in relation to the coronary ostia using an angiographic- and computed tomography (CT)-based analysis, and to determine the impact of valve position on coronary angiography...
We sought to evaluate the...
05/20/2020
Journal of Invasive Cardiology
Interaction Between Self-Expanding Transcatheter Heart Valves and Coronary Ostia: An Angiographically Based Analysis of the Evolut R/Pro Valve System
Original Contribution
03/10/2020
Abstract: Objectives. We sought to assess the position of the CoreValve Evolut R/Pro (Medtronic) with respect to the left coronary artery (LCA) ostium and evaluate the impact of implantation depth on this relationship. Methods. One hundred...
Abstract: Objectives. We sought to assess the position of the CoreValve Evolut R/Pro (Medtronic) with respect to the left coronary artery (LCA) ostium and evaluate the impact of implantation depth on this relationship. Methods. One hundred...
Abstract: Objectives. We sought...
03/10/2020
Journal of Invasive Cardiology
Servoz
Video
12/01/2021
During stent positioning after predilating with a non-compliant balloon, we observed major motion of our device in the left main coronary artery. Under those conditions, accurate stent placement was uncertain. To remedy this situation, we...
During stent positioning after predilating with a non-compliant balloon, we observed major motion of our device in the left main coronary artery. Under those conditions, accurate stent placement was uncertain. To remedy this situation, we...
During stent positioning after...
12/01/2021
Journal of Invasive Cardiology
Clinical Images
12/01/2021
During stent positioning after predilating with a non-compliant balloon, we observed major motion of our device in the left main coronary artery. Under those conditions, accurate stent placement was uncertain. To remedy this situation, we...
During stent positioning after predilating with a non-compliant balloon, we observed major motion of our device in the left main coronary artery. Under those conditions, accurate stent placement was uncertain. To remedy this situation, we...
During stent positioning after...
12/01/2021
Journal of Invasive Cardiology