Avoiding Intelligence Failures in the Cardiac Catheterization Laboratory: Strategies for the Safe and Rational Use of Dalteparin or Enoxaparin during Percutaneous Coronary Intervention

ABSTRACT: Low-molecular-weight heparin (LMWH) has been a mainstay for the management of acute coronary syndromes (ACS) for almost a decade. However, several recent developments have seriously threatened the prominence of this drug class: (i) the adoption of an early invasive strategy, frequently leading to percutaneous coronary intervention (PCI) where the dosing and monitoring of LMWH is unfamiliar to most operators, (ii) the results of the SYNERGY trial, which not only failed to establish the superiority of enoxaparin over unfractionated heparin with respect to efficacy, but also demonstrated more bleeding with LMWH, and (iii) the results of the REPLACE-2 and ACUITY trials, which have demonstrated the advantages of an ACS and PCI treatment strategy based on direct thrombin inhibition with bivalirudin. To confront these challenges, cardiologists committed to the continued use of LMWH must develop safe and user-friendly approaches to transition patients from the noninvasive to invasive settings. This review summarizes an approach that takes advantage of the fact that LMWH can be readily monitored with the point-of-care activated clotting time (ACT) assay. This assay is inexpensive, available in virtually every catheterization laboratory, and familiar to most operators who monitor unfractionated heparin (UFH). A key concept that is presented is that the ACT is a more accurate measure of LMWH-induced anticoagulation than of UFH-induced anticoagulation. Our preliminary work suggests that during PCI operators should target an ACT of 175 seconds in the presence, and 200 seconds in the absence, of adjunctive glycoprotein IIb/IIIa inhibition. Sheath removal is recommended at an ACT Mechanism of action of Low-Molecular-Weight Heparins LMWH is an indirect thrombin inhibitor formed by depolymerization of heparin using chemical or enzymatic methods.9 LMWH preparations have a mean molecular weight of 4,500–5,000 Daltons, with a distribution of 1,000 to 10,000 Daltons.9 Unfractionated heparin is a more heterogeneous mixture of polysaccharide chains ranging in molecular weight from 3,000–30,000 Daltons, with an average molecular weight of 15,000.10 Unlike direct thrombin inhibitors, which consist of a single molecular weight entity, LMWH represents a population of molecules with an average molecular weight lower than that of UFH (Figure 1). The mechanism of action of UFH and LMWH starts with the formation of a complex with antithrombin (Figure 2). LMWH’s catalytic activity then converts antithrombin from a slow to a rapid inactivator of coagulation factor Xa, accelerating antithrombin’s interaction with thrombin and Xa by a factor of approximately 1,000.10–12 Antithrombin has two active functional sites: the reactive center, Arg 393-Ser 394, and the LMWH binding site located at the amino terminus of the molecule.13 The binding of LMWH to antithrombin is mediated by a unique pentasaccharide sequence randomly distributed along the LMWH chain.12,14 Approximately one-third of the chains of UFH, but only 15–25% of the chains of LMWHs, contain the pentasaccharide sequence.10 After the LMWH has been bound to the heparin binding site on antithrombin, a conformational change in antithrombin occurs, and this significantly accelerates antithrombin’s inactivation of coagulation factor Xa.15,16 The binding of LMWH to antithrombin causes less inactivation of coagulation factor IIa (thrombin) when compared with that of unfractionated heparin.9 This is because inactivation of factor IIa requires the formation of a ternary complex in which heparin binds to both antithrombin and to a binding site on factor IIa (Figure 2).17 This ternary complex is formed on pentasaccharide containing chains of at least 18 saccharide units. However, unlike UFH, many of the LMWH do not contain sufficient saccharide units to form the ternary complex.9 It has been estimated that 25–50% of LMWH chains are sufficiently long to bridge antithrombin to factor IIa.10,17–20 Therefore, a major difference between UFH and LMWH is in their relative inhibitory activity against factor Xa and factor IIa (Table 1). Any pentasaccharide-containing heparin chain can inactivate factor Xa, but a minimum number of saccharide units is required to exert an inhibitory effect on factor IIa.10 Therefore, LMWH has a greater ratio of factor Xa to factor IIa inhibitory activity when compared with UFH, which has equivalent activity against these factors.10 Other antithrombogenic effects of LMWH include its promotion of the release of tissue factor pathway inhibitor (TFPI) from vascular endothelium, a reduction in the levels of von Willebrand factor (vWf), the inhibition of the procoagulant effects of leukocytes, the promotion of fibrinolysis and the inhibition of monocyte adhesion.21 Platelet factor 4 recently has been found to induce natural killer (NK) cells’ production of inflammatory cytokine IL-8, which may exert a prothrombotic effect in acute coronary syndromes (ACS).21 LMWH is less likely to be bound to platelet factor 4 than UFH, and thus exerts a less prothrombotic and potentially less proinflammatory effect than UFH.21 Pharmacokinetics of Low-Molecular-Weight Heparins LMWH exhibits less nonspecific binding to plasma proteins, endothelial cells and macrophages, and therefore has greater bioavailability than UFH.10 The diminished binding to macrophages results in reduced clearance by hepatic mechanisms; this is one of the reasons why renal clearance mechanisms are the major determinants of LMWH’s plasma half-life.10 The pharmacokinetics of LMWH are different from those of UFH after both IV and SC administration. The plasma anti-factor Xa activity is approximately two to four times longer than that of UFH, and this is regardless of the injected dose of the different forms of LMWH.10 This generally ranges from 2 to 4 hours after IV injection and from 4 to 6 hours after SC injection.10 The factor Xa inhibitory activity of LMWH persists longer than its inhibitory activity against factor IIa as a result of the more rapid clearance of longer heparin chains.10 The duration of anti-factor IIa activity of LMWH is only slightly longer than that of UFH.22 Because its route of elimination is via the renal system, the half-life of LMWH increases in patients with renal failure.9 LMWH dosing should therefore be reduced by 50% in patients with creatinine clearance Low-Molecular-Weight Heparins versus Unfractionated Heparin There are several features of LMWH that support its use during ACS and PCI. The most important advantage of LMWH versus UFH is that there is less platelet activation with LMWH (Figures 3 and 4).39,40 Platelet aggregation requires activation of glycoprotein (GP) IIb/IIIa receptors located on the surface of platelets, with fibrinogen acting as a cofactor for platelet activation. Standard UFH with its high molecular weight and longer saccharide chain activates platelet GP IIb/IIIa receptors, thereby potentiating platelet aggregation (Figure 5).41–47 The lower pro-aggregatory actions of LMWH have been detected in vitro and in vivo,44,47–55 and appear to decrease with decreasing molecular weight.52 In fact, LMWHs, with a molecular weight of 50% decrease in platelet count or skin lesions at injection sites.9 HIT is mediated by the HIT antibody recognizing the epitope on the platelet factor 4 (PF4)-heparin complex as an antigen.62 The HIT antibody binds to one or more PF4 regions conformationally modified by the interaction with heparin.9 At least 12–14 saccharide units within the heparin molecule are required to form the antigenic complex with PF4.9 Therefore, the risk of HIT antibody formation is lower during treatment with LMWH than with UFH.9 The better bioavailability, dose independent clearance and decreased affinity for heparin-binding proteins make the anticoagulant response to LMWHs more predictable than that to UFH.10 The Methodology of the Activated Clotting Time (ACT) and the Activated Partial Thromboplastin Time (aPTT) Activated Clotting Time (ACT). The activated clotting time (ACT) is a measure of the overall tendency of the blood to thrombose. It was first described by Hattersley in 1966 and came into clinical use in the mid-1970s to guide the administration and reversal of UFH during cardiopulmonary bypass.63 It is also used in point-of-care monitoring of the anticoagulation effect of UFH during cardiac catheterization and vascular surgery. The methodology of the ACT involves the collection of whole blood into a tube containing a magnet and an activator of coagulation, diatomaceous earth.64 This activator stimulates clot formation upon contact with whole blood via the intrinsic pathway.65 The tube is placed in a coagulation analyzer (e.g., Hemochron®, International Technidyne Corp., Edison, New Jersey).65 The magnet at the bottom of the tube is displaced once a clot is formed, activating the alarm on the analyzer (Figure 6).64 An advantage of the ACT in comparison to the aPTT is that at high doses of heparin, the dose-response relationship remains linear for the ACT. The aPTT usually becomes prolonged beyond measurable levels at heparin concentrations > 1 U/ml. This makes the aPTT unsuitable for monitoring heparin dosage during angioplasty and bypass surgery, as patients may require heparin levels > 1U/ml. The ACT has a graded response to heparin concentrations in the range of 1 U–5 U/ml. As a result, monitoring of heparin with the ACT may be more useful.66 Although it is used to monitor agents that possess both anti-IIa and anti-Xa activities, the ACT (and aPTT) are influenced predominantly by anti-IIa activity (Figure 7). Thus, if the ACT is used to monitor bivalirudin, one would expect a dramatic increase, e.g., from a baseline of approximately 110–130 sec to a post-bivalirudin bolus of 300–400 sec. In contrast, when using an agent such as LMWH that has a reduced ratio of anti-IIa:anti-Xa activity, the operator must anticipate a reduction in the magnitude of change from baseline values. The target ACT for the LMWH-treated patient is discussed below. The Activated Partial Thromboplastin Time (aPTT). The activated partial thromboplastin time (aPTT) measures the clotting time from the activation of factor XII to the formation of the fibrin clot, thus measuring the integrity of the intrinsic and common pathways of coagulation.65 The aPTT is usually used to monitor therapeutic heparin, hirudin and argatroban anticoagulation. However, as noted before, at high doses of heparin, the use of aPTT is not ideal. To measure the aPTT, blood is collected into a tube containing kaolin, an intrinsic pathway activator. A reagent of phospholipid is also provided in the aPTT assay;65 this is in contrast to the ACT assay, in which the platelets provide phospholipids. The measurement of the aPTT is generally performed in a hospital’s core laboratory facility, with results obtained within 30–60 minutes. This delay is an additional reason for which the ACT has been traditionally used in the cardiac catheterization laboratory and cardiovascular operating room settings where immediate results are often needed. Point-of-Care Monitoring Devices. There are point-of-care devices which have been developed to monitor both the ACT and the aPTT. These include The Hemochron® System (International Technidyne Corp.), which include the Hemochron Jr., Hemochron 801 and Hemochron 400 and Hemochron Jr. LR.67–71 Medtronic, Inc. (Minneapolis, Minnesota) has also developed point-of-care monitoring devices, which include the HemoTec and the Medtronic ACT II devices.72–74 There are other similar devices available such as Celite i-STAT ACT and the Hepcon/HMS devices.75–78 These devices are generally cartridge- or cuvette-based, allowing for less blood drawing and potentially greater reproducibility of results as operator variables such as the shaking of tubes no longer comes into play. Use of Low-Molecular-Weight Heparins during Percutaneous Coronary Intervention Anticoagulation during PCI is used to prevent thrombotic complications, including abrupt or subacute closure of the coronary vasculature and myocardial necrosis. LMWH offers theoretic advantages over UFH as an anticoagulant to prevent thrombotic arterial complications. However, UFH remains the most commonly used anticoagulant in PCI, in part because it is familiar and can be monitored easily. LMWH has seen increased use in the medical treatment of ACS, including patients with STEMI. A significant number of patients currently present to the cardiac catheterization laboratory for PCI already having received at least one, and occasionally several, doses of LMWH. Such patients pose several challenges and questions to the interventionist, such as: 1) Is there any value in using LMWH, as opposed to UFH, in PCI? 2) Can the LMWH that was administered prior to the patient’s arrival to the cath lab, or any additionally administered LMWH given in the cath lab be monitored using a bedside assay? 3) If so, what ACT value should be targeted? These questions and concerns have become all the more relevant and urgent given the emerging consensus, based on the SYNERGY trial, that switching antithrombotic agents appears to be associated with an increase in adverse events. Question 1. Is there any value in using LMWH, as opposed to UFH, in PCI? Theoretic advantages of LMWH versus UFH in PCI: LMWH demonstrates less platelet activation and less platelet endothelial interactions when compared with UFH (Figures 3–5).39,40 Although not proven, the propensity of UFH to activate platelets may have important clinical implications. For example, in the ASSENT III trial, over 6,000 acute MI patients were randomized to one of three arms: (i) full-dose fibrinolysis with UFH; (ii) half-dose fibrinolysis with UFH plus GP IIb/IIIa inhibition (abciximab); or (iii) full-dose fibrinolysis with LMWH (but no abciximab), and the composite endpoint to 30 days of death, reinfarction and refractory ischemia was examined. The worst outcomes were seen in the group of patients treated with full-dose tenecteplase (TNK) administered with UFH. Both combination therapy of half-dose TNK and abciximab, as well as the regimen of TNK with enoxaparin, showed a significant reduction in event rates (Figure 8).79 Thus, the beneficial effects of GP IIb/IIIa inhibition appear to be replicated by the use of LMWH, or seen from another perspective, the platelet activating effects of UFH require coadministration of GP IIb/IIIa inhibition to achieve results that could be achieved by using an antithrombin agent that does not activate platelets in the first place. This raises the question as to whether better antithrombins might reduce, or even eliminate, the need for adjunctive anti-GP IIb/IIIa therapy, as suggested by the results of the REPLACE-2 trial.30 Use of LMWH in elective and/or urgent PCI. Several studies have been conducted to evaluate the safety and efficacy of LMWH alone or in combination with GP IIb/IIIa inhibitors in PCI. The National Investigators Collaborating on Enoxaparin (NICE) group conducted two separate studies: NICE 1 and NICE 4. Patients in NICE 1 were administered IV enoxaparin alone at a dose of 1 mg/kg during PCI, while the NICE 4 group of patients were administered a reduced dose 0.75 mg/kg of IV enoxaparin, along with a standard dose of abciximab during PCI. In both groups of patients, bleeding complications and ischemic outcomes in hospital and at 30 days post PCI were infrequent. Thus, enoxaparin appears to be a safe and effective anticoagulant during PCI, both when administered alone and in combination with abciximab.80 Bhatt et al assessed the use of enoxaparin in combination with eptifibatide during PCI. The study was conducted on 261 PCI patients randomized to either LMWH plus eptifibatide, or UFH plus eptifibatide. There were no significant differences in the rates of bleeding nor in the rates of death, myocardial infarction or urgent target revascularization at 48 hours or 30 days.81 Another study by Kereiakes et al was conducted to assess the anticoagulant effect and clinical safety of dalteparin administered in combination with abciximab during PCI. This study concluded that IV dalteparin 60 IU/kg appeared to be safe and effective when administered in conjunction with a standard dose of abciximab.82 The SYNERGY trial. The SYNERGY trial was designed to be the definitive investigation for establishing the superiority of LMWH over UFH in the context of ACS managed invasively.5 Approximately 10,000 ACS patients were randomized to anticoagulation with either enoxaparin or UFH prior to undergoing PCI. There were no significant differences in the primary composite endpoint of death and myocardial infarction (MI) at 30 days, and the rate of successful PCI was similar between the two groups. However, bleeding complications were significantly greater in the LMWH group compared with UFH (Table 2). With respect to the increased bleeding in the enoxaparin arm, it is noteworthy that the UFH group was monitored using the ACT, while the LMWH group was not (Table 3). The failure to include monitoring of enoxaparin in the SYNERGY study design reflects the unsubstantiated conventional view that LMWH cannot be readily monitored with bedside assays, such as the activated clotting time (ACT), and may have contributed to the excessive bleeding rate seen in enoxaparin-treated patients. Indeed, one of the principal reasons that LMWH is generally not used during PCI is this notion that LMWH cannot be monitored. However, as discussed below, we have shown that the level of anticoagulation induced by intravenously administered dalteparin and enoxaparin can in fact be measured using the standard ACT test.6,7 The Safety and Efficacy of Enoxaparin in Percutaneous Coronary Intervention Patients (STEEPLE) Trial.83 The STEEPLE trial is the most important trial to address the potential role of LMWH in PCI. It is the first large (n = 3,528 patients), multicenter (n = 124 sites), prospective, randomized trial of LMWH versus UFH in PCI. STEEPLE randomized patients to one of two doses of IV enoxaparin (0.5 mg/kg or 0.75 mg/kg) or IV UFH, with GP IIb/IIIa inhibition use at the discretion of the operator. The primary endpoint of the study was non-coronary artery bypass graft surgery (CABG) major and minor bleeding at 48 hours. Secondary endpoints included various combinations of non-CABG major bleeds at 48 hours, death, nonfatal MI, or urgent target vessel revascularization at 30 days. The major finding of the study was that the primary end point of major bleeding was 57% lower in the enoxaparin arms than in the UFH arm. There were no significant differences in rates of death, death or MI, or death, MI and urgent target vessel revascularization, suggesting that the reduction in bleeding was not achieved at the expense of increased vulnerability to cardiac events. The STEEPLE trial provides important data to support the use of LMWH in elective PCI. However, one limitation of the trial was the failure to monitor the effects of enoxaparin with the ACT. Although some have emphasized the advantage of “no need to monitor,” many operators remain skeptical about the safety of using a strategy that precludes the ability to determine to any measurable degree the level of anticoagulation during PCI. While the advantage of not monitoring may be appealing in elective, low risk situations, there are a number of circumstances in which the ability to rapidly assess the anticoagulant status of the patient may be useful, including patients presenting with complex histories (e.g., a chronic renal failure patient who had recently received SC enoxaparin, thrombolytic therapy and now arrives at the cath lab with skin hypoperfusion due to cardiogenic shock), patients in whom the implications of thrombosis could be life-threatening (e.g., unprotected left main stenting), patients who initially were deemed low-risk who become high-risk in the course of their PCI (e.g., the unexpected appearance of intraluminal thrombus), and finally, in circumstances that are not entirely in the control of operators (e.g., medication dosing errors and drug administration errors; this latter point may be particularly relevant in cath labs where enoxaparin or dalteparin are administered from small preloaded syringes designed for SC administration). Meta-analysis. Dumaine et al reported a meta-analysis of randomized trials comparing the efficacy and safety of LMWH versus UFH as anticoagulants in the setting of PCI.84 The authors concluded that LMWH use during PCI is associated with similar efficacy and significantly reduced major bleeding complications when compared to UFH. Again, all the studies included in the analysis used a fixed dose of LMWH without monitoring the anticoagulant effect of LMWH. Question 2. Can LMWH be monitored readily and accurately with the ACT? The notion that LMWH is not amenable to monitoring was derived from studies using a SC route of administration, following which relatively low plasma levels are achieved. Furthermore, these studies were conducted in an era during which the default management strategy for ACS was noninvasive, where accurate knowledge of the specific level of anticoagulation in an individual patient may not have been as critical as in today’s era of invasive management. It is our contention that the anticoagulant effect of LMWH administered during PCI can and should be monitored, and that algorithms based on the timing from the last administered SC dose, such as those used in the SYNERGY trial, are inadequate.85 First, it is not always possible to determine the timing of the last dose of LMWH; not infrequently, there is inadequate documentation in the chart, particularly in the case of patients who may have had therapies initiated at one institution, and then are transferred to a tertiary care center for intervention. Second, the timing approach is based on a presumption that the pharmacokinetics of LMWH are always predictable. While this may be true in healthy volunteers, such is not the case for patients presenting with a variety of conditions such as obesity and renal dysfunction, conditions associated with an ever-increasing proportion of patients undergoing PCI. For example, an elderly diabetic patient with acute MI and hemodynamic compromise may have altered absorption from a SC dose because of poor skin perfusion, and altered elimination because of changes in an already compromised glomerular filtration rate. Thus, LMWH-treated patients most in need of accurate levels of anticoagulation are likely to be the most at risk for inaccurate dosing and excessive bleeding. These issues are likely to have contributed to the disappointing results of the SYNERGY trial. The ability to monitor UFH with the ACT or aPTT is determined predominantly by its anti-IIa activity, rather than by its anti-Xa activity (Figure 7). Thus, agents that are mainly anti-IIa, such as bivalirudin result in very high levels of ACT (i.e., 300–400 seconds range).29 In contrast, an agent such as pentasaccharide, which is almost exclusively anti-Xa, has very little influence on the ACT or aPTT.86 UFH, like LMWH, lies somewhere between these extremes, possessing both anti-IIa and anti-Xa activities (Figure 7). Among the LMWH agents, each agent has a relatively predictable and measurable anti-IIa activity. Because the ACT correlates with the anti-IIa activity, ACT is a reasonable measure of each drug concentration and is dependent on the anti-IIa inhibitory activity of that particular agent. Thus ACT should be a good guide to monitor the degree of anticoagulation and minimize bleeding risk provided that the operator recognizes that each agent impacts ACT to a variable but predictable level. The anti-IIa activity of UFH is determined by the formation of a ternary complex which requires at least 18 saccharide units.9 Because most UFH molecules contain at least 18 saccharide units, UFH has an anti-Xa to anti-IIa ratio that approximates unity.9 LMWHs, by virtue of their lower molecular weight and fewer saccharide units, have less anti-IIa activity and therefore a decreased ability to form the required ternary complex. The anti-Xa:anti-IIa ratio of several forms of commercially available LMWH range between 2 and 4, depending on the molecular weight distribution (Table 1).9 We have previously reported that the ACT can be used to monitor dalteparin administered intravenously at the time of PCI.6 Five minutes after 60 IU/kg of IV dalteparin, the ACT increased from levels of 120–130 sec to levels of 170–180 sec (and aPTT increased from 25–30 sec to 55–70 sec). Approximately 1 hour after the bolus dose, a decrease in the ACT and anti-IIa and anti-Xa levels was observed. This time course is favorable in the current era of stenting, where procedures are often completed within a half-hour, and raises the question as to whether the ACT could be used not only to determine the dosing of LMWH, but also to determine the timing of sheath removal (Figure 9). In addition, the rapid decline in LMWH concentration after IV bolus administration provides an anticoagulant profile that is more similar to bivalirudin, where hemostatic competence is rapidly restored after cessation of drug infusion, thereby reducing bleeding complications.30 An additional previously reported observation is that although UFH induced a greater increase in the ACT compared with dalteparin, there was a corresponding greater degree of variability in the response of the ACT to UFH compared with dalteparin.4 The tighter distribution of dalteparin-induced (in comparison to UFH-induced) peak ACT values has been confirmed in a recent randomized trial of PCI87 (Figure 10). This suggests that once a target ACT is reached, the corresponding blood levels of anticoagulant may be more reliably predicted than had UFH been administered. To extend our observations to enoxaparin, we performed additional monitoring studies using doses that more closely reflect those used in the STEEPLE trial. Specifically, in a population of 130 patients undergoing cardiac catheterization, the effects of intravenously administered enoxaparin 0.5 mg/kg, dalteparin 50 IU/kg, and UFH 50 units/kg were assessed with respect to changes in ACT, aPTT and anti-Xa levels.7 Both enoxaparin and dalteparin induced a significant rise in the ACT and aPTT (Figure 11), with an ACT dose-response approximately one-half the magnitude of that obtained using UFH. The elevation in the ACT was both significant and rapidly detectable; for example, within minutes of receiving IV enoxaparin 0.5 mg/kg, the ACT increased on average 41 seconds. The time course of changes in the ACT and aPTT after administration of enoxaparin and dalteparin was virtually identical, with a return to baseline at approximately 2 hours, suggesting a return to hemostatic competence that is as rapid as that seen using bivalirudin. An additional strategy for monitoring LMWH, specifically enoxaparin, is based on a bedside anti-Xa assay (ENOX test). Moliterno et al studied the Enox test in the ELECT study to determine a target range of anticoagulation for enoxaparin during PCI.88 This study was a prospective multicenter trial involving 445 patients receiving SC or IV enoxaparin. The rate of ischemic events was lowest in the mid-range of Enox times, and bleeding events increased with increasing Enox times. Lawrence et al studied the effect of IV enoxaparin on both the ACT and the Enox test in the setting of PCI.89 Sixty-seven consecutive patients undergoing PCI were given either 1 mg/kg of IV enoxaparin alone, or 0.75 mg/kg of IV enoxaparin plus eptifibatide. The ACT was measured before and 5 minutes following enoxaparin administration. The mean increase in the ACT was 77 ± 26 seconds in the 1 mg/kg group, and 69 ± 23 sec in the 0.75 mg/kg group (p 175 sec.82 In our study on an ACT-guided strategy, all patients (n = 104) received an initial IV bolus of 50 IU/kg of dalteparin. A bolus dose of GP IIb/IIIa inhibitors was administered at the discretion of the operator. No infusion of GP IIb/IIIa inhibitors was administered following the bolus dose, as per routine management at our institution.93,94 As mentioned previously, the minimum target ACT was 175 sec for patients who received GP IIb/IIIa inhibitors and 200 sec for patients who were not given GP IIb/IIIa inhibitors. Patients who did not achieve the target ACT after the initial 50 IU/kg were given supplemental boluses of dalteparin, with a rule-of-thumb that for every 10 IU/kg of dalteparin IV, the ACT will increase by approximately 10 sec. The mean baseline ACT was 138 ± 41 sec; after the initial bolus of dalteparin 50 IU/kg, this value rose to 231 ± 78 sec. In the 68 patients who achieved the target ACT after the initial bolus of dalteparin, the mean ACT was 261 ± 76 sec. In the 36 patients who required a supplemental bolus to achieve the target ACT, the mean initial post-dalteparin bolus ACT value was 188 ± 59 sec. The mean supplemental dose administered was 14 ± 6 IU/kg of dalteparin. The mean ACT after the supplemental dose was 239 ± 79 sec. The incidence of ischemic endpoints in our study was comparable to the ischemic endpoints reported in the SYNERGY5 and STEEPLE trials.83 However, bleeding complications in our study appeared to be lower than those reported in the LMWH arms of these trials possibly due to the close monitoring of the anticoagulant activity of dalteparin, nevertheless this finding could be entirely due to small sample size in our study. Based on our clinical experience, a convenient rule of thumb for achieving a target ACT level is that for every 0.1 mg/kg of enoxaparin IV or for every 10 IU/kg of dalteparin IV, the operator can anticipate a rise in the ACT of approximately 10 sec.8 Using doses from the STEEPLE trial83 and other published reports,80 a starting dose of enoxaparin 0.5 mg/kg IV or dalteparin 50 IU/kg appears reasonable, and will yield an elevation in the ACT of approximately 50 sec. Finally, our earlier study with dalteparin demonstrated that the increase in the ACT was sustained for a period of time relevant to current interventional practice. Using IV LMWH, the ACT is elevated for 40–60 min, with a decline in values at approximately 90 min.6 This raises the possibility that a decline in the ACT to a target level, for example Summary LMWH has been in use for over a decade and appears to be superior to unfractionated heparin in the non-invasive treatment of patients with acute coronary syndromes (ACS). The SYNERGY trial was designed to extend the indication of LMWH to include ACS patients managed with an early invasive approach and, when appropriate, percutaneous coronary intervention (PCI). The results of SYNERGY demonstrate that enoxaparin-treated patients may undergo PCI with a similar rate of success compared to UFH-treated patients. However, patients who were randomized to enoxaparin suffered a significantly greater rate of hemorrhagic complication. It is noteworthy that a major distinction between the two groups was that monitoring was used in the UFH-treated patients, but not in the LMWH-treated group. This failure to include monitoring in the trial design reflects an unsubstantiated bias that LMWH-treated patients are not amenable to monitoring with a readily available bedside assay such as the ACT. Arguably, the reluctance of PCI operators to embrace LMWH, despite a number of theoretic and practical advantages (e.g., less thrombocytopenia, diminished platelet activation, low cost, partial reversibility with protamine), is related in a large part to the perceived inability to monitor LMWH. Our earlier studies and more recent observations have demonstrated that, in fact, both dalteparin and enoxaparin can be monitored with the ACT. Based on these preliminary observations, we have proposed a minimum target ACT of 175 sec for LMWH in PCI performed with GP IIb/IIIa inhibition and a minimum target ACT of 200 sec for LMWH in PCI without GP IIb/IIIa inhibition, which are supported by our previous observation and others (Figure 13). We have also a proposed a target ACT value of From the Division of Cardiology, Department of Medicine, State University of New York (SUNY) Health Science Center at Brooklyn, New York. The authors report no conflicts of interest regarding the content herein. Manuscript submitted January 29, 2009, provisional acceptance given March 12, 2009, final version accepted June 12, 2009. Address for correspondence: Jonathan D. Marmur, MD, Professor of Medicine, Director of Cardiac Catheterization and Interventional Cardiology, SUNY Downstate Medical Center, 450 Clarkson Avenue, Box 1257, Brooklyn, NY 11203-2098. E-mail: jonathan@marmur.com
1. Cohen M, Demers C, Gurfinkel EP, et al. A comparison of low-molecular-weight heparin with unfractionated heparin for unstable coronary artery disease. Efficacy and Safety of Subcutaneous Enoxaparin in Non-Q-Wave Coronary Events Study Group. N Engl J Med 1997;337:447–452.

2. Antman EM, McCabe CH, Gurfinkel EP, et al. Enoxaparin prevents death and cardiac ischemic events in unstable angina/non-Q-wave myocardial infarction. Results of the thrombolysis in myocardial infarction (TIMI) 11B trial. Circulation 1999;100:1593–1601.

3. Invasive compared with non-invasive treatment in unstable coronary-artery disease: FRISC II prospective randomised multicentre study. FRagmin and Fast Revascularisation during InStability in Coronary artery disease Investigators. Lancet 1999;354:708–715.

4. Cannon CP, Weintraub WS, Demopoulos LA, et al, the TACTICS-Thrombolysis in Myocardial Infarction 18 Investigators. Comparison of Early Invasive and Conservative Strategies in Patients with Unstable Coronary Syndromes Treated with the Glycoprotein IIb/IIIa Inhibitor Tirofiban 10.1056/NEJM200106213442501. N Engl J Med 2001;344:1879–1887.

5. Ferguson JJ, Califf RM, Antman EM, et al. Enoxaparin vs unfractionated heparin in high-risk patients with non-ST-segment elevation acute coronary syndromes managed with an intended early invasive strategy: Primary results of the SYNERGY randomized trial. JAMA 2004;292:45–54.

6. Marmur JD, Anand SX, Bagga RS, et al. The activated clotting time can be used to monitor the low molecular weight heparin dalteparin after intravenous administration. J Am Coll Cardiol 2003;41:394–402.

7. Cavusoglu E, Lakhani M, Marmur JD. The activated clotting time (ACT) can be used to monitor enoxaparin and dalteparin after intravenous administration. J Invasive Cardiol 2005;17:416–421.

8. Marmur JD, Poludasu S, Feit A, et al. Activated clotting time (ACT)-guided intravenous dalteparin dosing during percutaneous coronary intervention. J Invasive Cardiol 2008;20:323–327.

9. Hirsh J, Warkentin TE, Shaughnessy SG, et al. Heparin and low-molecular-weight heparin: Mechanisms of action, pharmacokinetics, dosing, monitoring, efficacy, and safety. Chest 2001;119:64S–94S.

10. Weitz JI. Low-molecular-weight heparins. N Engl J Med 1997;337:688–698.

11. Hirsh J, Anand SS, Halperin JL, Fuster V. Guide to anticoagulant therapy: Heparin: A statement for healthcare professionals from the American Heart Association. Circulation 2001;103:2994–3018.

12. Hirsh J, Warkentin TE, Raschke R, et al. Heparin and low-molecular-weight heparin: Mechanisms of action, pharmacokinetics, dosing considerations, monitoring, efficacy, and safety. Chest 1998;114:489S–510S.

13. Perry DJ. Antithrombin and its inherited deficiencies. Blood Rev 1994;8:37–55.

14. Choay J, Petitou M, Lormeau JC, et al. Structure-activity relationship in heparin: A synthetic pentasaccharide with high affinity for antithrombin III and eliciting high anti-factor Xa activity. Biochem Biophys Res Commun 1983;116:492–499.

15. Marcum JA, McKenney JB, Rosenberg RD. Acceleration of thrombin-antithrombin complex formation in rat hindquarters via heparinlike molecules bound to the endothelium. J Clin Invest 1984;74:341–350.

16. Klein B, Faridi A, von Tempelhoff GF, et al. A whole blood flow cytometric determination of platelet activation by unfractionated and low molecular weight heparin in vitro. Thromb Res 2002;108:291–296.

17. Danielsson A, Raub E, Lindahl U, Bjork I. Role of ternary complexes, in which heparin binds both antithrombin and proteinase, in the acceleration of the reactions between antithrombin and thrombin or factor Xa. J Biol Chem 1986;261:15467–15473.

18. Anderson W, Harthill JE. Molecular weight dependence of heparin anti-factor Xa activity: Influence of method. Thromb Res 1981;21:557–564.

19. Rosenberg RD, Jordan RE, Favreau LV, Lam LH. Highly active heparin species with multiple binding sites for antithrombin. Biochem Biophys Res Commun 1979;86:1319–1324.

20. Jordan RE, Favreau LV, Braswell EH, Rosenberg RD. Heparin with two binding sites for antithrombin or platelet factor 4. J Biol Chem 1982;257:400–406.

21. Selwyn AP. Prothrombotic and antithrombotic pathways in acute coronary syndromes. Am J Cardiol 2003;91:3H–11H.

22. Bara L, Samama M. Pharmacokinetics of low molecular weight heparins. Acta Chir Scand Suppl 1990;556:57–61.

23. Caranobe C, Barret A, Gabaig AM, et al. Disappearance of circulating anti-Xa activity after intravenous injection of standard heparin and of a low molecular weight heparin (CY 216) in normal and nephrectomized rabbits. Thromb Res 1985;40:129–133.

24. Palm M, Mattsson C. Pharmacokinetics of heparin and low molecular weight heparin fragment (fragmin) in rabbits with impaired renal or metabolic clearance. Thromb Haemost 1987;58:932–935.

25. Collet JP, Montalescot G, Choussat R, et al. Enoxaparin in unstable angina patients with renal failure. Int J Cardiol 2001;80:81–82.

26. Maraganore JM, Bourdon P, Jablonski J, et al. Design and characterization of hirulogs: A novel class of bivalent peptide inhibitors of thrombin. Biochemistry 1990;29:7095–7101.

27. Bittl JA, Chaitman BR, Feit F, et al. Bivalirudin versus heparin during coronary angioplasty for unstable or postinfarction angina: Final report reanalysis of the bivalirudin angioplasty study. Am Heart J 2001;142:952–959.

28. Lincoff AM, Bittl JA, Kleiman NS, et al. The REPLACE 1 trial: A pilot study of bivalirudin versus heparin during percutaneous coronary intervention with stenting and GP IIb/IIIa blockade. J Am Coll Cardiol 2002;39:16–17.

29. Lincoff AM, Kleiman NS, Kottke-Marchant K, et al. Bivalirudin with planned or provisional abciximab versus low-dose heparin and abciximab during percutaneous coronary revascularization: Results of the Comparison of Abciximab Complications with Hirulog for Ischemic Events Trial (CACHET). Am Heart J 2002;143:847–853.

30. Lincoff AM, Bittl JA, Harrington RA, et al. Bivalirudin and provisional glycoprotein IIb/IIIa blockade compared with heparin and planned glycoprotein IIb/IIIa blockade during percutaneous coronary intervention: REPLACE-2 randomized trial. JAMA 2003;289:853–863.

31. Stone GW, McLaurin BT, Cox DA, et al. Bivalirudin for patients with acute coronary syndromes. N Engl J Med 2006;355:2203–2216.

32. Stone GW, Witzenbichler B, Guagliumi G, et al. Bivalirudin during primary PCI in acute myocardial infarction. N Engl J Med 2008;358:2218–2230.

33. Leung LL. New anticoagulants. In: Date UT, ed., 2005.

34. Bivalirudin — Drug information. In: Online UTD (ed). Lexi-Corp, Inc Online, 2005.

35. Maraganore JM, Adelman BA. Hirulog: A direct thrombin inhibitor for management of acute coronary syndromes. Coron Artery Dis 1996;7:438–448.

36. Robson R, White H, Aylward P, Frampton C. Bivalirudin pharmacokinetics and pharmacodynamics: Effect of renal function, dose and gender. Clin Pharmacol Ther 2002;71:433–439.

37. Bauer KA. Clinical use of fondaparinux. Up to date. 2004 Online 12.1.

38. Yusuf S, Mehta SR, Chrolavicius S, et al. Comparison of fondaparinux and enoxaparin in acute coronary syndromes. N Engl J Med 2006;354:1464–1476.

39. Cella G, Girolami A, Sasahara AA. Platelet activation with unfractionated heparin at therapeutic concentrations and comparison with low-molecular-weight heparin and with a direct thrombin inhibitor. Circulation 1999;99:3323.

40. Xiao Z, Theroux P. Platelet activation with unfractionated heparin at therapeutic concentrations and comparisons with a low-molecular-weight heparin and with a direct thrombin inhibitor. Circulation 1998;97:251–256.

41. Sobel M, Fish WR, Toma N, et al. Heparin modulates integrin function in human platelets. J Vasc Surg 2001;33:587–594.

42. Komarnicki M, Kazmierczak M, Haertle D. Standard heparin and low molecular weight heparin effect on spontaneous platelet aggregation measured in whole blood and in platelet-rich plasma. Acta Haematol Pol 1993;24:263–265.

43. Eika C. Platelet refractory state induced by heparin. Scand J Haematol 1972;9:665–672.

44. Salzman EW, Rosenberg RD, Smith MH, et al. Effect of heparin and heparin fractions on platelet aggregation. J Clin Invest 1980;65:64–73.

45. Chong BH, Ismail F. The mechanism of heparin-induced platelet aggregation. Eur J Haematol 1989;43:245–251.

46. Chen JH, Karlberg KE, Sylven C. Heparin and low molecular weight heparin but not hirudin stimulate platelet aggregation in whole blood from acetylsalicylic acid treated healthy volunteers. Thromb Res 1991;63:319–329.

47. Heinrich D, Gorg T, Schulz M. Effects of unfractionated and fractionated heparin on platelet function. Haemostasis 1988;18(Suppl 3):48–54.

48. Dunn FW, Soria C, Thomaidis A, et al. Interactions of platelets with standard heparin and low molecular weight fractions. Nouv Rev Fr Hematol 1984;26:249–253.

49. Mikhailidis DP, Barradas MA, Mikhailidis AM, et al. Comparison of the effect of a conventional heparin and a low molecular weight heparinoid on platelet function. Br J Clin Pharmacol 1984;17:43–48.

50. Kawano K, Ikeda Y, Handa M, et al. Enhancing effect by heparin on shear-induced platelet aggregation. Semin Thromb Hemost 1990;16(Suppl):60–65.

51. Mastacchi R, Stanzani L, Barbanti M, et al. Interaction of heparin and heparin fractions with human platelets. Thromb Res 1982;28:275–280.

52. Brace LD, Fareed J. Heparin-induced platelet aggregation: Dose/response relationships for a low molecular weight heparin derivative (PK 10169) and its subfractions. Thromb Res 1986;42:769–782.

53. Westwick J, Scully MF, Poll C, Kakkar VV. Comparison of the effects of low molecular weight heparin and unfractionated heparin on activation of human platelets in vitro. Thromb Res 1986;42:435–447.

54. Mastacchi R, Barbanti M, Bianchini P, Osima B. Interaction of a new low molecular weight heparin (OP/LMWH) with human platelets. Agents Actions 1986;17:512–514.

55. Cella G, Scattolo N, Luzzatto G, Girolami A. Effects of low-molecular-weight heparin on platelets as compared with commercial heparin. Res Exp Med (Berl) 1984;184:227–229.

56. Hansen JB, Sandset PM. Differential effects of low molecular weight heparin and unfractionated heparin on circulating levels of antithrombin and tissue factor pathway inhibitor (TFPI): A possible mechanism for difference in therapeutic efficacy. Thromb Res 1998;91:177–181.

57. Hansen JB, Sandset PM, Huseby KR, et al. Differential effect of unfractionated heparin and low molecular weight heparin on intravascular tissue factor pathway inhibitor: Evidence for a difference in antithrombotic action. Br J Haematol 1998;101:638–646.

58. Hansen JB, Naalsund T, Sandset PM, Svensson B. Rebound activation of coagulation after treatment with unfractionated heparin and not with low molecular weight heparin is associated with partial depletion of tissue factor pathway inhibitor and antithrombin. Thromb Res 2000;100:413–417.

59. Sandset PM, Bendz B, Hansen JB. Physiological function of tissue factor pathway inhibitor and interaction with heparins. Haemostasis 2000;30(Suppl 2):48–56.

60. Wong GC, Giugliano RP, Antman EM. Use of low-molecular-weight heparins in the management of acute coronary artery syndromes and percutaneous coronary intervention. JAMA 2003;289:331–342.

61. Montalescot G, Philippe F, Ankri A, et al. Early increase of von Willebrand factor predicts adverse outcome in unstable coronary artery disease: Beneficial effects of enoxaparin. French Investigators of the ESSENCE Trial. Circulation 1998;98:294–299.

62. Chong BH. Heparin-induced thrombocytopenia. J Thromb Haemost 2003;1:1471–1478.

63. Bowers J, Ferguson JJ. Use of the activated clotting time in anticoagulation monitoring of intravascular procedures. Tex Heart Inst J 1993;20:258–263.

64. Marmur JD. Low molecular weight heparin in the cardiac catheterization laboratory: CD-ROM 2002.

65. Van Cott EM, Laposta M. Coagulation. In: Jacobs DS, et al (eds). The Laboratory Test Handbook, 5th Edition. Cleveland: Lexi-Comp. 2001, pp.327–358.

66. Hirsh J, Raschke R, Warkentin TE, et al. Heparin: Mechanism of action, pharmacokinetics, dosing considerations, monitoring, efficacy, and safety. Chest 1995;108:258S–275S.

67. Fitch JC, Mirto GP, Geary KL, et al. Point-of-care and standard laboratory coagulation testing during cardiovascular surgery: Balancing reliability and timeliness. J Clin Monit Comput 1999;15:197–204.

68. Searles B, Nasrallah F, Graham S, Tozer M. Electronic data management for the Hemochron Jr. Signature coagulation analyzer. J Extra Corpor Technol 2002;34:182–184.

69. Jaryno S, Bennett K, Loder C, et al. Validation of a new whole blood coagulation monitoring system. J Extra Corpor Technol 2002;34:271–275.

70. Uden DL, Seay RE, Kriesmer PJ, et al. The effect of heparin on three whole blood activated clotting tests and thrombin time. ASAIO Trans 1991;37:88–91.

71. Colby CE, Sheehan A, Benitz W, et al. Maintaining adequate anticoagulation on extracorporeal membrane oxygenation therapy: Hemochron Junior Low Range versus Hemochron 400. J Extra Corpor Technol 2003;35:35–38.

72. Avendano A, Ferguson JJ. Comparison of Hemochron and HemoTec activated coagulation time target values during percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 1994;23:907–910.

73. Cohen M. Monitoring Anticoagulation during percutaneous coronary interventions. J Thromb Thrombolysis 1995;1:285–288.

74. Koster A, Despotis G, Gruendel M, et al. The plasma supplemented modified activated clotting time for monitoring of heparinization during cardiopulmonary bypass: A pilot investigation. Anesth Analg 2002;95:26–30, Table of contents.

75. Paniccia R, Fedi S, Carbonetto F, et al. Evaluation of a new point-of-care celite-activated clotting time analyzer in different clinical settings. The i-STAT celite-activated clotting time test. Anesthesiology 2003;99:54–59.

76. Raymond PD, Ray MJ, Callen SN, Marsh NA. Heparin monitoring during cardiac surgery. Part 1: Validation of whole-blood heparin concentration and activated clotting time. Perfusion 2003;18:269–276.


Advertisement