Skip to main content

ADVERTISEMENT

chronic occlusion

12/01/2015

Thomas Davis, MD

 

St. John Hospital and Medical Center, St. Clair Shores, Michigan

Thomas Davis, MD   St. John Hospita...
The Ocelot catheter allows for safe, quick, and efficient crossing of peripheral arterial CTOs while eliminating, or significantly reducing, fluoroscopic exposure and associated contrast administration.
The Ocelot catheter allows for safe, quick, and efficient crossing of peripheral arterial CTOs while eliminating, or significantly reducing, fluoroscopic exposure and associated contrast administration.
The Ocelot catheter allows for...
12/01/2015
Vascular Disease Management
05/20/2015
Transcollateral approach has afforded crossing success and ultimately successful treatment in many complex cases, but it requires finesse on the part of the operator.
Transcollateral approach has afforded crossing success and ultimately successful treatment in many complex cases, but it requires finesse on the part of the operator.
Transcollateral approach has...
05/20/2015
Vascular Disease Management
05/20/2015

Vinayak Subramanian, BS1; George L. Adams, MD, MHS2

 

1Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina; 2Rex Hospital, University of North Carolina Health System, Raleigh, North Carolina

Vinayak Subramanian, BS1; George L. A...
This paper is focused on the techniques and tools required for successfully using the transcollateral approach to cross CTOs in the peripheral artery tree. 
This paper is focused on the techniques and tools required for successfully using the transcollateral approach to cross CTOs in the peripheral artery tree. 
This paper is focused on the...
05/20/2015
Vascular Disease Management
06/04/2013
The TruePath CTO Device for chronic total occlusion (Boston Scientific), which has a diamond-coated distal tip that spins at 13,000 revolutions per minute, can help to break through extremely calcified lesions.
The TruePath CTO Device for chronic total occlusion (Boston Scientific), which has a diamond-coated distal tip that spins at 13,000 revolutions per minute, can help to break through extremely calcified lesions.
The TruePath CTO Device for...
06/04/2013
Vascular Disease Management
06/04/2013

Jon C. George, MD

 

Division of Cardiovascular Medicine, Deborah Heart and Lung Center, Browns Mills, New Jersey

Jon C. George, MD   Division of Car...
The authors present a case of endovascular revascularization of a chronic total occlusion via retrograde use of a re-entry catheter, which allows an alternative strategy for revascularization when antegrade approaches fail.
The authors present a case of endovascular revascularization of a chronic total occlusion via retrograde use of a re-entry catheter, which allows an alternative strategy for revascularization when antegrade approaches fail.
The authors present a case of...
06/04/2013
Vascular Disease Management
03/07/2013

Jon C. George, MD,

 

Division of Cardiovascular Medicine, Deborah Heart and Lung Center, 200 Trenton Road, Browns Mills, New Jersey

Jon C. George, MD,   Division of Ca...
This case report presents a patient with calcified infrapopliteal CTO with critical limb ischemia that was successfully crossed using a CTO catheter.
This case report presents a patient with calcified infrapopliteal CTO with critical limb ischemia that was successfully crossed using a CTO catheter.
This case report presents a...
03/07/2013
Vascular Disease Management