The purpose of this study was to compare cardiac hemodynamics and prevalence of HFpEF between coarctation of aorta patients with vs without obesity, and to assess the relationship between obesity and HFpEF in this population.
The purpose of this study was to compare cardiac hemodynamics and prevalence of HFpEF between coarctation of aorta patients with vs without obesity, and to assess the relationship between obesity and HFpEF in this population.
Robert S. Zhang, MD1, Eugene Yuriditsky, MD1, Eric Bailey, MD2, Lindsay Elbaum, MD1, Allison A. Greco, MD3, Radu Postelnicu, MD3, Vikramjit Mukherjee, MD3, Norma Keller, MD1, Carlos L. Alviar, MD1, James M. Horowitz, MD1, Sripal Bangalore, MD, MHA1
Robert S. Zhang, MD1, Eugene Yuridits...
The objective of the study was to examine and compare the hemodynamic impact of saddle vs non-saddle pulmonary embolism in a selected patient population.
The objective of the study was to examine and compare the hemodynamic impact of saddle vs non-saddle pulmonary embolism in a selected patient population.
The study's aim was to evaluate the added value of invasive hemodynamic assessment in patients with unexplained shortness of breath (SOB) undergoing echocardiographic assessment using the most accepted echocardiographic definition of...
The study's aim was to evaluate the added value of invasive hemodynamic assessment in patients with unexplained shortness of breath (SOB) undergoing echocardiographic assessment using the most accepted echocardiographic definition of...
A 78-year-old man with symptomatic bicuspid severe aortic stenosis with LVEF 50% was planned for transcatheter aortic valve replacement (TAVR). His CT scan revealed calcified bicuspid aortic valve (Sievers Type 1), calcified raphe with...
A 78-year-old man with symptomatic bicuspid severe aortic stenosis with LVEF 50% was planned for transcatheter aortic valve replacement (TAVR). His CT scan revealed calcified bicuspid aortic valve (Sievers Type 1), calcified raphe with...
The use of simultaneous left ventricular and ascending aortic pressure tracings by cardiac catheterization is the gold standard of care for accurate hemodynamic assessment of aortic stenosis severity in patients with equivocal echocardiogram....
The use of simultaneous left ventricular and ascending aortic pressure tracings by cardiac catheterization is the gold standard of care for accurate hemodynamic assessment of aortic stenosis severity in patients with equivocal echocardiogram....
The correlation between hemodynamics and clinical phenotypes/symptoms in adults post Fontan procedure has not been well studied. Moreover, the “expected” hemodynamics in those who are asymptomatic remain unclear.
The correlation between hemodynamics and clinical phenotypes/symptoms in adults post Fontan procedure has not been well studied. Moreover, the “expected” hemodynamics in those who are asymptomatic remain unclear.
In our patient, the alteration in cardiac hemodynamics after a transjugular intrahepatic portosystemic shunt (TIPS) procedure made the oxygen saturation from the superior vena cava a more accurate representation of systemic oxygenation.
In our patient, the alteration in cardiac hemodynamics after a transjugular intrahepatic portosystemic shunt (TIPS) procedure made the oxygen saturation from the superior vena cava a more accurate representation of systemic oxygenation.
Nitroglycerin produces significant coronary vasodilation, increasing vessel caliber and to a lesser extent, flow responses, and at the same time, reduces afterload (systemic arterial dilation) and preload due to venodilation. Practically...
Nitroglycerin produces significant coronary vasodilation, increasing vessel caliber and to a lesser extent, flow responses, and at the same time, reduces afterload (systemic arterial dilation) and preload due to venodilation. Practically...
The hemodynamic features of subacute aortic regurgitation include equalization of left ventricular pressure and the aortic pressure during diastole, a mildly increased pulse pressure, and systemic hypotension.
The hemodynamic features of subacute aortic regurgitation include equalization of left ventricular pressure and the aortic pressure during diastole, a mildly increased pulse pressure, and systemic hypotension.