Skip to main content

Robert L. Minor, Jr., MD, FACC

08/01/2008
ABSTRACT: Four years of follow-up renal function and survival data were obtained on 544 patients who underwent 714 successful renal artery stenosis (RAS) stent revascularizations. The mean serum creatinine (SCr) was unchanged at 4 years (1.6...
ABSTRACT: Four years of follow-up renal function and survival data were obtained on 544 patients who underwent 714 successful renal artery stenosis (RAS) stent revascularizations. The mean serum creatinine (SCr) was unchanged at 4 years (1.6...
ABSTRACT: Four years of...
08/01/2008
Journal of Invasive Cardiology
Cath Lab Spotlight
11/05/2019
Our new Heart & Vascular program started in the fall of 2017, and between our first and second years, we experienced a 55% increase in our cath lab volumes.
Our new Heart & Vascular program started in the fall of 2017, and between our first and second years, we experienced a 55% increase in our cath lab volumes.
Our new Heart & Vascular program...
11/05/2019
Cath Lab Digest
Randomized Trial of VasoStat Versus TR Band Following Radial Artery Access for Catheterization Procedures
Original Contribution
01/21/2021
VasoStat (VS; Forge Medical) is a recently developed radial artery compression device (RCD) producing focused puncture-site pressure.  We compared time to hemostasis and patient experience with VS vs balloon compression with the TR Band...
VasoStat (VS; Forge Medical) is a recently developed radial artery compression device (RCD) producing focused puncture-site pressure.  We compared time to hemostasis and patient experience with VS vs balloon compression with the TR Band...
VasoStat (VS; Forge Medical) is...
01/21/2021
Journal of Invasive Cardiology
Randomized Trial of VasoStat Versus TR Band Following Radial Artery Access for Catheterization Procedures
Original Contribution
02/01/2021
We compared time to hemostasis and patient experience with VasoStat vs balloon compression with the TR Band (Terumo) in a randomized, prospective trial among subjects undergoing radial catheterization procedures with same-day discharge.
We compared time to hemostasis and patient experience with VasoStat vs balloon compression with the TR Band (Terumo) in a randomized, prospective trial among subjects undergoing radial catheterization procedures with same-day discharge.
We compared time to hemostasis...
02/01/2021
Journal of Invasive Cardiology
Case Series
09/10/2023
Addressing the technical challenges of 5 Fr transradial access endovascular procedures for treating femoral, iliac, renal, subclavian and carotid artery disease.
Addressing the technical challenges of 5 Fr transradial access endovascular procedures for treating femoral, iliac, renal, subclavian and carotid artery disease.
Addressing the technical...
09/10/2023
Cath Lab Digest