Skip to main content

Douglas Beinborn, RN, BSN, MA

05/03/2008
I have a question concerning some issues here at our EP lab thought you may be able to steer me in the right direction. I am looking for some information on the protective measures everyone else is using to reduce the radiation exposure to...
I have a question concerning some issues here at our EP lab thought you may be able to steer me in the right direction. I am looking for some information on the protective measures everyone else is using to reduce the radiation exposure to...
I have a question concerning...
05/03/2008
EP Lab Digest
05/01/2008
Cardiac resynchronization therapy (CRT), also known as biventricular pacing, provides symptomatic relief, clinical improvement, prolonged survival, and a better quality of life for many heart failure patients. CRT defibrillators (CRT-D) also...
Cardiac resynchronization therapy (CRT), also known as biventricular pacing, provides symptomatic relief, clinical improvement, prolonged survival, and a better quality of life for many heart failure patients. CRT defibrillators (CRT-D) also...
Cardiac resynchronization...
05/01/2008
EP Lab Digest
05/01/2008
Dr. Shen and his colleagues at the Mayo Clinic conducted the Syncope Evaluation in the Emergency Department Study (SEEDS). The genesis of the study was based on the central question whether an area designated for syncope evaluation in the...
Dr. Shen and his colleagues at the Mayo Clinic conducted the Syncope Evaluation in the Emergency Department Study (SEEDS). The genesis of the study was based on the central question whether an area designated for syncope evaluation in the...
Dr. Shen and his colleagues...
05/01/2008
EP Lab Digest
Feature Story
05/03/2008
The Medtronic LOCALISA system provides real-time, nonfluoroscopic, 3-D visualization of conventional intracardiac catheter electrodes. It is sufficiently accurate for detailed catheter mapping and the creation of linear or complex RF lesion...
The Medtronic LOCALISA system provides real-time, nonfluoroscopic, 3-D visualization of conventional intracardiac catheter electrodes. It is sufficiently accurate for detailed catheter mapping and the creation of linear or complex RF lesion...
The Medtronic LOCALISA system...
05/03/2008
EP Lab Digest
Feature Story
05/03/2008
Nearly one million patients are discharged from the hospital annually with the diagnosis of heart failure, an increase of 159.4% from 1979 to 1998.
Nearly one million patients are discharged from the hospital annually with the diagnosis of heart failure, an increase of 159.4% from 1979 to 1998.
Nearly one million patients are...
05/03/2008
EP Lab Digest
Perspectives
05/03/2008
This product received 510(k) clearance on December 21st, 1999, allowing Acuson to market the AcuNav diagnostic ultrasound catheter in the United States. The AcuNav has many useful indications.
This product received 510(k) clearance on December 21st, 1999, allowing Acuson to market the AcuNav diagnostic ultrasound catheter in the United States. The AcuNav has many useful indications.
This product received 510(k)...
05/03/2008
EP Lab Digest
Review
05/01/2008
Use of the Chronicle Implantable Hemodynamic Monitor system has the potential to allow more precise titration of drugs by providing data continuously during rest and exercise, and when drugs and doses are modified.
Use of the Chronicle Implantable Hemodynamic Monitor system has the potential to allow more precise titration of drugs by providing data continuously during rest and exercise, and when drugs and doses are modified.
Use of the Chronicle Implantable...
05/01/2008
EP Lab Digest
Feature Story
02/26/2009
Douglas Beinborn, MA, RN, and colleagues describe a new system being used at the Mayo Clinic to assess patients at risk for sudden cardiac arrest.
Douglas Beinborn, MA, RN, and colleagues describe a new system being used at the Mayo Clinic to assess patients at risk for sudden cardiac arrest.
Douglas Beinborn, MA, RN, and...
02/26/2009
EP Lab Digest
09/26/2012
BackgroundCardiac rhythm disturbances are relatively common in the pediatric age group, occurring in about 1 in 1,000 children. Although most of these arrhythmias tend to be benign, some can be debilitating or life-threatening. These...
BackgroundCardiac rhythm disturbances are relatively common in the pediatric age group, occurring in about 1 in 1,000 children. Although most of these arrhythmias tend to be benign, some can be debilitating or life-threatening. These...
BackgroundCardiac rhythm...
09/26/2012
EP Lab Digest
Spotlight Interview
10/30/2008
Along with the lab facilities, the Heart Rhythm Center includes the Implantable Device Clinic, Arrhythmia Clinic, Atrial Fibrillation Clinic, Long QT/Inherited Arrhythmia Clinic, Pediatric and Adolescent Arrhythmia Clinic, and Syncope Clinic.
Along with the lab facilities, the Heart Rhythm Center includes the Implantable Device Clinic, Arrhythmia Clinic, Atrial Fibrillation Clinic, Long QT/Inherited Arrhythmia Clinic, Pediatric and Adolescent Arrhythmia Clinic, and Syncope Clinic.
Along with the lab facilities,...
10/30/2008
EP Lab Digest