Skip to main content

ADVERTISEMENT

Gaku Nakazawa, MD

08/01/2008
ABSTRACT: Ikari is a new guide catheter for transradial intervention (TRI) that produces stronger back-up force by utilizing an unfavorable angle between the subclavian and brachiocephalic arteries. We report the initial results of the Ikari...
ABSTRACT: Ikari is a new guide catheter for transradial intervention (TRI) that produces stronger back-up force by utilizing an unfavorable angle between the subclavian and brachiocephalic arteries. We report the initial results of the Ikari...
ABSTRACT: Ikari is a new guide...
08/01/2008
Journal of Invasive Cardiology
Original Contribution
11/05/2009
ABSTRACT: Objective. We sought to clarify the mechanisms of backup force for right coronary artery intervention. Background. Backup force of a guiding catheter is important for successful percutaneous coronary intervention (PCI); however,...
ABSTRACT: Objective. We sought to clarify the mechanisms of backup force for right coronary artery intervention. Background. Backup force of a guiding catheter is important for successful percutaneous coronary intervention (PCI); however,...
ABSTRACT: Objective. We sought...
11/05/2009
Journal of Invasive Cardiology
Original Contribution
11/29/2012
Abstract: Objectives. To demonstrate safety and efficacy of new 6 Fr intra-aortic balloon pumping (IABP) system. Background. Access-site complications have been reported to increase adverse events following PCI. Some reports have shown...
Abstract: Objectives. To demonstrate safety and efficacy of new 6 Fr intra-aortic balloon pumping (IABP) system. Background. Access-site complications have been reported to increase adverse events following PCI. Some reports have shown...
Abstract: Objectives. To...
11/29/2012
Journal of Invasive Cardiology
Original Contribution
07/30/2013
Second-generation DES have alleviated the safety concerns of late stent thrombosis by addressing issues of polymer biocompatibility, stent design and optimizing drug loads and release kinetics. This study was designed to evaluate the...
Second-generation DES have alleviated the safety concerns of late stent thrombosis by addressing issues of polymer biocompatibility, stent design and optimizing drug loads and release kinetics. This study was designed to evaluate the...
Second-generation DES have...
07/30/2013
Journal of Invasive Cardiology
Original Contribution
01/29/2014
There may be a trade-off between longitudinal strength and conformability. This in vivo study investigates longitudinal strength and conformability of various stent platforms following stent implantation in rabbit iliac arteries.
There may be a trade-off between longitudinal strength and conformability. This in vivo study investigates longitudinal strength and conformability of various stent platforms following stent implantation in rabbit iliac arteries.
There may be a trade-off between...
01/29/2014
Journal of Invasive Cardiology
Original Contribution
09/02/2015
We retrospectively analyzed 207 CTO lesions in 195 patients in a single center between January 2008 and December 2011 and found that over  one-half of CTO lesions can be treated with high success and low complication rates by TRI if the...
We retrospectively analyzed 207 CTO lesions in 195 patients in a single center between January 2008 and December 2011 and found that over  one-half of CTO lesions can be treated with high success and low complication rates by TRI if the...
We retrospectively analyzed 207...
09/02/2015
Journal of Invasive Cardiology