ADVERTISEMENT
Case Report
Use of Multiple Stents to Seal Off an Epicardial Pseudoaneurysm
July 2003
Pseudoaneurysms of saphenous vein grafts are rare following coronary artery bypass surgery. They occur most often at the proximal anastomosis secondary to vessel layer disruption. Rarely do they occur distally. We report the case of a pseudoaneurysm involving the saphenous vein graft to a circumflex marginal branch at the distal anastomosis site.
Case Report. A 69-year-old male presented initially with shortness of breath and chest pain; an exercise stress echocardiogram was positive for inducible ischemia, and subsequent cardiac catheterization revealed triple-vessel disease. The patient underwent coronary artery bypass surgery. His hospital course was complicated by a large left pleural effusion, and a diagnosis of post-cardiotomy syndrome was made that responded to thoracentesis and steroid therapy.
Prior to commencing cardiac rehabilitation, an echocardiogram 3 months following surgery revealed a 6.0 cm mass compressing the posterior wall of the left ventricle. A computed tomography (CT) scan of the chest with contrast showed a 6.0 x 6.0 cm mass with enhancement, and therefore a left heart catheterization was undertaken. This revealed the bypass grafts all to be patent. However, the saphenous vein graft to the circumflex marginal branch at the distal anastomosis revealed a leak contained in the pericardial sac with the formation of a pseudoaneurysm, compressing the left ventricular cavity.
A covered stent was not immediately available, so we harvested a piece of the saphenous vein and mounted it on a 3 mm AVE stent. We were unable to successfully deploy the stent to the distal segment, most likely secondary to the compression of the distal vein graft by the pseudoaneurysm.
A 3.0 x 13 mm Tristar stent was deployed across the neck of the aneurysm, but the jet of contrast still persisted. A second 3.0 x 16 mm NIR stent was deployed within the first stent. After placement of 2 stents, there was significant reduction in the leak; we then inserted a third 3.0 x 8.0 mm Tristar stent within the first 2 stents followed by a prolonged balloon inflation. This was successful in occluding the pseudoaneurysm and preserving the flow into the circumflex marginal branch. We think the most likely mechanism was that 3 stents deployed concentrically diminished the flow of blood across the neck of the aneurysm, and then a prolonged inflation allowed complete thrombosis within the aneurysm.
At 6-week follow-up, repeat CT scan revealed the size of the mass to be smaller with no contrast enhancement (which is indicative of flow) of the mass. We performed a stress echocardiogram. The patient walked 8 minutes on standard Bruce Protocol, achieving 85% of his target heart rate without any electrocardiographic or wall motion abnormalities to suggest ischemia.
Discussion. Pseudoaneurysms of vein grafts have been reported early after surgery, but the majority of them were detected late after surgery, as late as seventeen years.1–12 Presentations can include postoperative mediastinitis, fistulas with erosion of the vein grafts to the right atrium or anterior chest wall.8,12–14,16 They may be caused by tension on the graft anastomosis. In addition, infection can develop at the site of suture lines, causing these pseudoaneurysms.7,12–14 Myocardial infarction secondary to embolization has also been described.15 The dreaded complication of these pseudoaneurysms is obviously rupture, with the potential for death.1,2,11
The treatment has varied as the field of interventional cardiology has progressed. The majority of cases are still treated with surgical resection with or without redo bypass surgery.1,3,11,12 Rare cases have been described using autologous vein grafts mounted on stents.17,18 Coil embolization of the pseudoaneurysms has also been described.4,19
The case described is the first reported case of pseudoaneurysm closure using multiple stents while preserving distal run-off in the vein graft. Because the occurrence is rare, the experience is quite limited. The covered stents will simplify distal anastomotic pseudoaneurysm management, provided the stent is deliverable to the site. Our approach can be considered as an alternative when bulky covered stents are not deliverable to a distal pseudoaneurysm.
1. Mohara J, Konishi H, Kato M, et al. Saphenous vein graft pseudoaneurysm rupture after coronary artery bypass grafting. Ann Thorac Surg 1998;65:831–832.
2. Rosin MD, Ridley PD, Maxwell PH. Rupture of a pseudoaneurysm of a saphenous vein coronary arterial bypass graft presenting with a superior caval venous obstruction. Int J Cardiol 1989;25:121–123.
3. Nakamura T, Shimamoto M, Yamazaki F, et al. Pseudoaneurysm of saphenous vein graft after CABG. Jpn J Thorac Surg 1995;48:333–336.
4. Dimitri WR, Reid AW, Dunn FG. Leaking false aneurysm of right coronary saphenous vein graft: Successful treatment by percutaneous coil embolisation. Br Heart J 1992;68:619–620.
5. Khabeishvili G, Shaburishvili T, Wann S, et al. Saphenous vein graft pseudoaneurysm: Diagnosis by transesophageal echocardiography and magnetic resonance imaging. J Am Soc Echocardiogr 1995;8:338–340.
6. Sherry CS, Harms SE. MR imaging of pseudoaneurysms in aortocoronary bypass graft. J Comput Assist Tomogr 1989;13:426–429.
7. de Haan HPJ, Huysmans HA, Weeda HWH, et al. Anastomotic pseudoaneurysm after aorto-coronary bypass grafting. Thorac Cardiovasc Surg 1985;33:55–56.
8. Jukema JW, van Dijkman PRM, van der Wall EE. Pseudoaneurysm of a saphenous vein coronary artery bypass graft with a fistula draining into the right atrium. Am Heart J 1992;124:1397–1399.
9. Karwande SV, Sharp SD. Saphenous vein graft pseudoaneurysm presenting as a mediastinal mass. Tex Heart Inst J 1990;17:129–132.
10. Kim D, Guthaner DF, Wexler L. Transcatheter embolization of a leaking pseudoaneurysm of a saphenous vein aortocoronary bypass graft. Cathet Cardiovasc Diagn 1983;9:591–594.
11. Kallis P, Keogh BE, Davies MJ. Pseudoaneurysm of aortocoronary vein graft secondary to late venous rupture: Case report and literature review. Br Heart J 1993;70:189–192.
12. Wight JN Jr., Salem D, Vannan MA, et al. Asymptomatic large coronary artery saphenous vein bypass graft aneurysm: A case report and review of the literature. Am Heart J 1997;133:454–460.
13. Smith JA, Goldstein J. Saphenous vein graft pseudoaneurysm formation after postoperative mediastinitis. Ann Thorac Surg 1992;54:766–768.
14. Smith P, Qureishi S, Yacoub MH. Dehiscence of infected aortocoronary vein graft suture lines: Cause of late pseudoaneurysm of ascending aorta. Br Heart J 1983;50:193–195.
15. Nathaniel C, Missri JC. Coronary artery bypass graft pseudoaneurysm communication with the right atrium: A case report and review. Cathet Cardiovasc Diagn 1996;38:80–82.
16. Mahy IR, Walton S. Successful treatment of false aneurysm of a saphenous vein bypass graft with fistula to the anterior chest wall using “covered” intracoronary stents. Heart 1998;80:527–529.
17. Wong SC, Kent KM, Mintz GS, et al. Percutaneous transcatheter repair of a coronary aneurysm using composite autologous cephalic vein-coated Palmaz-Schatz biliary stent. Am J Cardiol 1995;76:990–991.
18. Kaplan BM, Stewart RE, Sakwa MP, O’Neill WW. Repair of a coronary pseudoaneurysm with percutaneous placement of a saphenous vein allograft attached to a biliary stent. Cathet Cardiovasc Diagn 1996;37:208–212.
19. Ducksoo K, Guthaner DF, Wexler L. Transcatheter embolisation of a leaking pseudoaneurysm of saphenous vein aortocoronary bypass graft. Cathet Cardiovasc Diagn 1983;9:591–594.