Myocardial Injury After Apparently Successful Coronary Stenting With or Without Balloon Dilation: Direct Versus Conventional Ste
April 2002
Direct stenting (DS) without balloon predilation is a novel approach in the percutaneous treatment of coronary artery lesions. This approach, besides reducing aggression to the vessel wall, may also significantly lower the rate of procedural ischemic complications because the dissections created by balloon inflation are immediately sealed by the endoprosthesis. Stenting without balloon dilation may decrease trauma, incidence of dissection and distal embolization, leading to a better outcome.1–4
Cardiac enzymes troponin T, troponin I, creatine kinase (CK) and its isoform CKMB are particularly useful not only for the diagnosis of myocardial infarction, but also for the diagnosis of myocardial necrosis.5,6 However, troponins were shown to be more sensitive than CKMB7,8 for the detection of this minor damage missed by conventional markers which are prognostically important.9–11 The reported incidence of troponin T or I release after percutaneous coronary intervention (PCI) ranges between 13–44%, with the incidence higher after stenting.7,12,13
We hypothesized that DS would decrease the myocardial injury because it causes less trauma. However, data regarding the potential benefits of direct stenting in this field are scarce. The purpose of this study was to measure cardiac troponin T (cTnT), CK and CKMB fraction after apparently successful elective stent implantation with conventional stenting (CS) or stenting without balloon predilation (DS) and to compare the procedural myocardial injury between these two approaches.
METHODS
We reviewed our institutional interventional database and identified all patients who underwent percutaneous coronary intervention from May 1999 to February 2001. Cases with infarcted myocardium at the intervened artery site, recent myocardial infarction (MI), pre-procedural enzyme elevation, bundle branch block morphology in electrocardiogram, and sidebranch arising from the lesion location were excluded. We identified 60 patients who fulfilled our criteria. These patients were then divided into two groups: 1) conventional stenting (CS) patients (n = 23); and 2) direct stenting (DS) patients (n = 37).
PCI was performed after obtaining multiple views of the coronary lesion. After crossing the lesion with a 0.014´´ guidewire, interventionist preference determined the procedure to be performed. Initial balloon dilation in the CS group was carried out with percutaneous transluminal coronary angioplasty balloons inflated at nominal pressures (6–8 atmospheres). Multiple balloon inflations were performed if needed. Stenting in both groups was accomplished with the use of second-generation, pre-loaded tubular stents (Jostent and ACS MultiLink) which were implanted at high pressure (> 12 atmospheres). Stent-artery ratio was 1.1:1. DS was accomplished with the delivery balloon and a high-pressure single inflation. Post-dilation was not performed in any patients in either group. During the procedure, an intravenous bolus dose of 10,000 units of standard heparin was given to maintain an activated clotting time > 300 seconds and continued for 6 hours in addition to ticlopidine (250 mg twice daily for 30 days) or clopidogrel (300 mg loading dose, then 75 mg/day for 30 days) and aspirin (300 mg, indefinitely). Glycoprotein IIb/IIIa receptor blockers were not used in any patients. Quantitative coronary angiography (QCA) was performed with the use of an automatic edge detection system (General Electric DLX Angiographic Systems, GE Medical Systems Europe, Sedex, France).
Troponin T, CK and CKMB measurements were done just before and 16 hours after the intervention. A second-generation commercial ELISA cTnT assay (Boehringer Mannheim Corporation) was used to measure cTnT with a cut-off of 0.1 ng/dl. Total CK (normal 0.1 ng/dl; the difference between the groups was analyzed with the Chi-square test. Mean cTnT values were compared with the Mann-Whitney U-test. A p-value 2.5 mm. Stenting was successful in all patients. There was no stent loss or imprecise stent placement in the DS group.
There were no abnormalities in any of the 3 enzymes in either group before the procedure. At 16 hours, cTnT was elevated in 5 out of 23 patients (21.7%) in the CS group and 4 out of 37 patients (10.8%) in the DS group. Although both the incidence and mean numerical values of cTnT were observed to be higher in the CS group than in the DS group at 16 hours post-procedure, these values did not reach statistical significance (p > 0.05) (Table 1).
CK and CKMB levels were not elevated (above 2 times normal) in any of the patients. Only 2 patients had CK elevation > 200 IU 16 hours post-procedure. Patient and angiographic variables of the troponin positive and negative groups are listed in Tables 2 and 3. The increase in cTnT was not clearly predictable by any factor. There was no association between lesion type, stenosis severity, balloon length or inflation duration with the release of cTnT (Table 3).
DISCUSSION
The extensive use of stents in the treatment of coronary artery disease led cardiologists to simplify the procedure by introducing the concept of stenting without predilation, i.e., direct stenting. Several studies confirmed the safety and feasibility of the procedure with success rates greater than 90%.1,2,4 In addition to reductions in procedure time, fluoroscopy time and procedural costs, balloon-induced dissections were also reported to be lower.1,2
Animal studies revealed that endothelial denudation was lower in the DS group compared to the CS group, which may mean less vascular wall trauma and thrombosis risk.3,14 Also, Webb et al. reported less atheromatous embolic debris during intervention in saphenous vein grafts with DS compared to CS, which may lead to a lesser degree of myocardial damage.4 The authors reported that stents reduced thrombus dislodgement and embolization by entrapping friable material. Repeated balloon inflations to obtain a greater luminal diameter are also eliminated.15 We also hypothesized that limitation of vessel trauma to the stented segment might decrease the myocardial injury in the DS group. Avoiding vessel trauma outside the stented segment by avoiding predilation with long balloons (a lesion that could usually be stented with a 9 mm stent is predilated with a 20 mm balloon) may decrease procedure-related complications. However, although the incidence of cTnT release is higher in the CS group than in the DS group (21.8% versus 10.8%, respectively), these values did not reach statistical significance (p > 0.05). This could have been due to the small number of patients involved. There was no difference in balloon length between the groups. However, the potential pitfalls of DS should always be kept in mind. Although stenosis severity was not reported to be an indicator of successful direct stenting,1 passing a stent through a severe undilated stenosis might be more traumatic, leading to increased distal embolization.
Most studies reported that elevation of enzymes after PCI has been linked to the occurrence of in-lab complications. Post-procedural CKMB elevation was previously reported to be due to prolonged ischemia, sidebranch occlusion, peri-procedural transient vessel occlusion and distal embolization.16–21 Since we excluded patients with a sidebranch arising from the lesion, there was no sidebranch occlusion in our cohort. This might explain the lack of detectable CKMB elevation in this cohort. Transient ischemia without cell necrosis was also reported to lead minor amounts of cTnI elevation.22,23 Although we found no difference between the transient occlusion time of the groups with elevated and normal cTnT levels in our cohort, elimination of the balloon predilation prior to stenting might decrease the duration of ischemia and related necrosis.
The reported incidence of troponin T or I release was higher after stenting compared to balloon angioplasty.7,12,13 Shyu et al. recently reported that incidence of cTnT release was 29% with stenting compared to 13% with PTCA (p
1. Briguori C, Sheiban I, De Gregorio J, et al. Direct coronary stenting without predilation. J Am Coll Cardiol 1999;34:1910–1915.
2. Herz I, Assali A, Solodky A, et al. Effectiveness of coronary stent deployment without predilation. Am J Cardiol 1999;84:89–91.
3. Rogers C, Parikh S, Seifert P, Edelman E. Endothelial cell seeding: Remnant endothelium after stenting enhances vascular repair. Circulation 1996;94:2909–2914.
4. Webb J, Carere R, Virmani R, et al. Retrieval and analysis of particulate debris following saphenous vein graft intervention. J Am Coll Cardiol 1999;34:468–475.
5. Mair J, Artner-Dworzak E, Dienstl A, et al. Early detection of acute myocardial infarction by measurement of mass concentration of creatine kinase MB. Am J Cardiol 1991;68:1545–1550.
6. Wu AHB. Creatine kinase isoforms in ischemic heart disease. Clin Chem 1989;35:7–13.
7. La Vecchia L, Bedogni F, Finocchi G, et al. Troponin T, troponin I, and CK-MB mass in the detection after elective coronary stenting. Coron Artery Dis 1996;7:535–540.
8. Shyu KG, Kuan PL, Cheng JJ, Hung CR. Cardiac troponin T, creatine kinase and its isoform release after successful percutaneous transluminal coronary angioplasty with or without stenting. Am Heart J 1998;135:862–867.
9. Hamm CW, Ravkilde J, Gerhardt W, et al. The prognostic value of serum troponin T in unstable angina. N Engl J Med 1992;327:146–150.
10. Lindahl B, Venge P, Wallentin L, for the FRISC Study Group. Relation between troponin T and the risk of subsequent cardiac events in unstable coronary disease. Circulation 1996;93:1651–1657.
11. Harrington R, Lincoff M, Califf R, et al. Characteristics and consequences of myocardial infarction after percutaneous coronary intervention: Insights from the coronary angioplasty versus excisional atherectomy trial (CAVIAT). J Am Coll Cardiol 1995;25:1693–1699.
12. Ravkilde J, Nissen H, Mickley H, et al. Cardiac troponin T and CK-MB mass release after visually successful percutaneous transluminal coronary angioplasty in stable angina pectoris. Am Heart J 1994;127:13–20.
13. Karim MA, Shinn M, Oskarsson H, et al. Significance of troponin T and CK-MB mass release after percutaneous transluminal coronary angioplasty. Am J Cardiol 1995;76:521–523.
14. Rogers C, Karnovsky M, Edelman E. Inhibition of experimental neointimal hyperplasia and thrombosis depends on the type of vascular injury and the site of drug administration. Circulation 1993;88:1215–1221.
15. Heldman AW, Brinker JA. Direct stenting: Is the future near? Cathet Cardiovasc Intervent 2000;50:382–383.
16. Geft I, Fishbein M, Ninomiya K, et al. Intermittent brief periods of ischemia have a cumulative effect and may cause myocardial necrosis. Circulation 1982;66:1150–1153.
17. Detre K, Holmes D, Holubkov R, et al. Incidence and consequences of periprocedural occlusion: The 1985–1986 National Heart, Lung, and Blood Institute PTCA Registry. Circulation 1990;82:739–750.
18. Abdelmeguid A, Topol E, Whitlow P, et al. Significance of mild transient release of creatine kinase MB fraction after percutaneous coronary interventions. Circulation 1996;94:1528–1536.
19. Karim MA, Shinn M, Oskarsson H, et al. Significance of troponin T and CK-MB mass release after percutaneous transluminal coronary angioplasty. Am J Cardiol 1995;76:521–523.
20. Genser N, Mair J, Friedrich G, et al. Uncomplicated successful percutaneous transluminal coronary angioplasty does not affect cardiac troponin T plasma concentrations. Am J Cardiol 1996;78:127–128.
21. Talasz H, Genser N, Mair J, et al. Side-branch occlusion during percutaneous transluminal coronary angioplasty. Lancet 1992;339:1380–1382.
22. Bleier J, Vorderwinkler KP, Falkensammer J, et al. Different intracellular compartmentalizations of cardiac troponins and myosin heavy chains: A casual connection to their different early release after myocardial damage. Clin Chem 1998;44:1912–1918.
23. Feng YJ, Chen C, Fallon JT, et al. Comparison of cardiac troponin I, creatine kinase-MB, and myoglobin for detection of acute ischemic myocardial injury is a swine model. Am J Clin Pathol 1998;110:70–77.
24. Garbarz E, Iung B, Lefévre G, et al. Frequency and prognostic value of cardiac troponin I elevation after coronary stenting. Am J Cardiol 83:515–518.
25. Saadettin SM, Habbab MA, Sobki SH, Ferns GA. Minor myocardial injury after elective uncomplicated successful PTCA with or without stenting: Detection by cardiac troponins. Cathet Cardiovasc Intervent 2001;53:188–192.
26. EPIC Investigators. Use of a monoclonal antibody directed against the platelet glycoprotein IIb/IIIa receptors in high-risk coronary angioplasty. N Engl J Med 1994;330:956–961.
27. Tardiff BE, Califf RM, Tcheng JE, et al. Clinical outcomes after detection of elevated cardiac enzymes in patients undergoing percutaneous intervention. IMPACT-II Investigators. Integrilin (eptifibatide) to Minimize Platelet Aggregation and Coronary Thrombosis-II. J Am Coll Cardiol 1999;33:88–96.
28. Hamon M, Richardeau Y, Lecluse E, et al. Direct coronary stenting without balloon predilation in acute coronary syndromes. Am Heart J 1999;138:55–59.
29. Gibson CM, de Lemos JA, Murphy SA, et al., for the TIMI Study Group. Combination therapy with abciximab reduces angiographically evident thrombus in acute myocardial infarction: A TIMI 14 substudy. Circulation 2001;103:2550–2554.
30. Neuman FJ, Blasini R, Schmitt C, et al. Effect of glycoprotein IIb/IIIa receptor blockade on recovery of coronary flow and left ventricular function after the placement of coronary-artery stents in acute myocardial infarction. Circulation 1998;98:2695–2701.