Morphology and Location of Restenosis Following Bare Metal Coronary Stenting

Marc J. Schweiger, MD, Ehsan Ansari, MD, Gregory R. Giugliano, MD, *James Mathew, MD, Ashequl Islam, MD, John Morrison, MD, James R. Cook, MD
April 2006
Coronary stent implantation decreases restenosis rates when compared with percutaneous transluminal coronary angioplasty (PTCA),1,2 and the use of these endoluminal scaffolds has increased dramatically since their introduction.3 The most compelling reasons for stent placement are their favorable angiographic and clinical outcomes. Despite a reduction in restenosis associated with coronary stenting, clinical recurrence following bare metal stenting still occurs in approximately 15–20% of patients.4 Treatment for in-stent restenosis is associated with a high rate of recurrence, particularly for nonfocal lesions.5 Diffuse in-stent restenosis can be treated with balloon PTCA and vascular brachytherapy.6 Intracoronary brachytherapy, including hospitalization costs, is expensive and subsequent restenosis risk persists. Thus, there has been excitement about the development of drug-eluting stents (DES) and the associated reduction in in-stent restenosis.7–9 Restenosis rates, while reduced, persist following the placement of DES and appear to be particularly prevalent outside the stent.8,10 The pattern of in-stent restenosis, following placement of bare metal stents, has been previously described as either diffuse (lesion > 10 mm in length) or focal (11 However, new lesions outside the stent have not been well characterized. Thus, we developed an angiographic classification to include lesions external, but proximal, to the stent. We then examined the relationship between lesion location and morphology to timing of symptomatic presentation leading to repeat angiography. Methods Patient population. We reviewed our interventional cardiology database for all percutaneous coronary interventions from January 1998 through December 2001 (N = 3,997). There were 203 patients treated with a coronary stent who underwent a repeat coronary angiogram within 30 days to 1 year following stent implantation, who had either in-stent restenosis or a new lesion within 10 mm of the stented segment, and all were included in the study. For the purposes of our analysis, both in-stent restenosis and new lesions within 10 mm of the stented segment will be referred to as restenotic lesions. Repeat angiography was always symptom-driven. Of the 203 patients, 177 underwent repeat coronary intervention and 26 underwent coronary artery bypass surgery. Patients with stents in coronary bypass grafts were excluded. Demographic information was entered into the interventional database at the time of the procedure, and additional information was collected retrospectively from hospital charts by a data coordinator. The relationship between the type of restenosis and the timing of repeat procedures was analyzed for patients with a single restenotic lesion. Angiographic analysis. All angiograms were analyzed by two independent observers using visual inspection. Restenosis was defined as ? 50% stenosis either within the stent or within 10 mm from the proximal or distal stent edge. Lesion length was measured as the distance in millimeters from the proximal shoulder to the distal shoulder of the lesion in the projection with the least amount of foreshortening, utilizing the diameter of the guiding catheter as a reference. Classification of restenosis. Lesions were classified by two independent angiographers, with a third angiographer adjudicating any discrepancies in lesion classifications (Figure 1). The following classification scheme was used: • Class I: Patients with stenosis inside of the stent. Ia. Focal ( 10 mm within the stent) lesion. Ic. Total occlusion TIMI flow grade 0. • Class II: Patients with stenosis outside of the stent. IIa. Diffuse proliferative lesion (restenosis > 10 mm in length extending outside of the stent). IIb. Edge restenosis: lesion at the proximal and/or distal margin of the stent. IIc. New lesion within 10 mm of either the proximal or distal edge of the stent. Statistical analysis. Data are presented as mean ± standard deviation (SD) or proportions where appropriate and compared by the t-test or Chi-squared test, respectively. Multivariable analysis was accomplished using logistic regression (STATA version 8.1; STATA Corporation College Station, Texas). A value of p Results A total of 130 men and 73 women were included. The average age was 63 ± 12 years. Diabetes mellitus was present in 36% of patients, medically-treated hypertension in 69%, and hyperlipidemia in 73% of patients (Table 1). There were no differences in the baseline characteristics of patients by group classification. There was a trend toward more Class II patients being male (67% Class II vs. 57% Class I), and for Class I patients to have more likely presented with unstable angina (57%) than the Class II patients (44%). Of the 234 lesions analyzed, Class I lesions were found in 52% and Class II lesions occurred in 48% of patients. Both lesion types were further classified as discussed in the Methods section (Table 2). There were no significant differences in vessel size, stent length and technique (direct stenting versus predilatation) between the two groups. The mean time interval between procedures was 130 days (median = 116). Thirty percent of patients with restenotic lesions underwent their repeat procedure within 1 to 3 months, 49% within 3 to 6 months and 21% within 6 to 12 months. Patients who developed restenosis within 1 to 3 months were more likely to have an edge restenosis as compared to other lesion types (p Discussion Our results demonstrate the frequent occurrence (48%) of significant stenosis outside of bare metal stents in patients presenting with symptoms following coronary stent deployment. The majority of these stenoses also involve stenosis inside of the stent (diffuse proliferative and edge). Drug-eluting stents markedly reduce the incidence of in-stent restenosis,7–9 but are unlikely to affect stenosis outside of the stent.8,10 Therefore, these data suggest that stenosis outside the stent will continue to be a concern even with the widespread use of DES. Restenosis has been the Achilles heel of percutaneous coronary intervention. Several pharmaceutical trials have shown no benefit in reducing restenosis12,13 following coronary angioplasty. The development of coronary stents has been associated with a 30% decrease in restenosis,1,2 but clinical trials have shown that restenosis still occurred frequently, particularly in patients with longer lesions, small diameter vessels and diabetes mellitus.14,15 Focal in-stent restenosis can generally be treated with balloon angioplasty with acceptably low recurrent restenosis rates.11,16,17 More extensive in-stent restenosis has unacceptably high recurrent restenosis rates following balloon angioplasty and debulking techniques.6,11,18,19 Coronary brachytherapy has been shown to decrease recurrent restenosis in high-risk patients,20–23 but is capital-intensive and not always successful. Thus, the cardiology community embraced the excellent results to date with DES.8,9 In the SIRIUS trial, in-stent restenosis was reduced by 90% and target lesion revascularization by 75% with the use of the Cypher™ DES (Cordis Corp., Miami, Florida). The difference in recurrent restenosis at the proximal margin was not significantly different between DES and bare metal stents, and the majority of revascularizations were for lesions outside of the stent.8 In the TAXUS IV trial,9 there were significant reductions in clinical, angiographic and intravascular ultrasound measures of restenosis with the Taxus® DES (Boston Scientific Corp., Natick, Massachusetts). Target lesion revascularization at 9 months was reduced by 73% with the use of the Taxus DES, while target vessel revascularization was reduced by 61%. Of the patients receiving a Taxus stent who had undergone repeat revascularization at 9 months, 56% had lesions outside the stented segment. Mehran et al.11 previously proposed an angiographic criteria for in-stent restenosis which was confirmed by intravascular ultrasound. In this analysis, 34% of patients had diffuse proliferative restenosis. Among the 37% of patients with focal restenotic lesions, the proportion occurring outside the stent was not specified. We expanded the Mehran classification to include restenosis at the edges of the stent and within 10 mm of the stent edge. In a consecutive series of patients undergoing repeat coronary intervention, over a 3-year period incorporating advanced stent technology, we found that 48% of restenotic lesions occur outside of the stent. Our classification system was aimed at understanding the mechanism for the location of the restenotic lesion and it overlaps with the concept of in-stent (including the stented segment) and in-segment (including the stented segment and 5 mm margins on either side).9 Class I lesions would all be in-stent. Among Class II lesions, IIa would be in-segment, IIb would be in-segment and the majority of IIc lesions would be out of segment. The etiology of restenosis occurring external to the stent is likely multifactorial. Diffuse proliferative restenosis, which occurred in 34% of lesions outside of the stent (Class II), is an aggressive restenotic response primarily within the stent, with extension to the stent edge and beyond. Patients receiving DES, who otherwise would have diffuse proliferative restenosis, would be expected to continue to have restenosis occur outside of the stent where the effects of the drug would be least active. Edge restenosis, which had previously been described following coronary brachytherapy24 and implantation of DES,8 occurred in 32% of Class II lesions. Balloon injury, caused by pre- and postdilatation balloon inflation and balloon overhang of the stent during implantation, can cause a concomitant injury-restenotic response.25 Patients with edge restenosis presented earlier than patients with other patterns of restenosis. This is consistent with a typical plain-old balloon angioplasty response to restenosis in which clinical recurrence within 6 to 12 weeks is most common.26 Additionally, Attila et al. hypothesized that edge restenosis may be related to low-oscillating shear stress causing expression of several growth factors, which leads to intimal proliferation and restenosis. These changes are probably more prominent within the first few months after stent implantation, which in turn may explain the earlier occurrence of edge restenosis.27 Edge restenosis, seen in the SIRIUS trial,8 occurred more commonly at the proximal edge. This may reflect preferential diffusion of sirolimus downstream and/or a manifestation of postdilatation strategies, including pullback of the stent balloon, which would cause more tissue injury proximally. Following the release of the SIRIUS trial results, recommendations aimed at reducing restenosis outside the stent emphasized employing diligence during implantation to minimize balloon injury outside the stented segment, and the use of longer DES has been advocated to cover the entire diseased segment. It has recently been shown that longer DES lengths do increase the risk of restenosis, though not as much as longer bare metal stents.28 The E-SIRUIS trial,29 utilizing these techniques, showed a decreased incidence of in-segment, out-of-stent restenosis. In SIRIUS,8 the incidence of out-of-segment restenosis was highest in those patients likely to have diffuse disease, e.g., diabetes and long lesions. In “real world” DES implantation, it is likely that many patients with more diffuse disease will be treated. Intravascular ultrasound studies have shown that coronary artery disease is a diffuse disease and angiography will often underestimate or not detect significant atherosclerotic plaque.30 It is plausible, though unproven, that the utilization of intravascular ultrasound to identify appropriate areas of the artery to implant the stent would minimize stent edge injury. Our study demonstrated the frequent occurrence of restenosis outside bare metal coronary stents. In the era of DES, treatment to minimize restenosis needs to incorporate strategies to decrease balloon injury in the non-stented segment. Using longer DES should help reduce, but will not eliminate, this problem. Study limitations. This is a retrospective analysis and is, therefore, subject to the limitations pertinent to this type of clinical investigation. The study was performed in a single institution and has the limitations inherent in any single-center analysis. Differences in patient population and operator technique may not allow generalization of our results to all institutions. As a regional center, the majority of our patients required urgent percutaneous coronary intervention, and thus our patient population may differ from those treated at other institutions. There were 7 interventionalists who worked during the time frame of this study and it is possible that difference in technique could have contributed to the outcome. However, all operators worked with the same interventional fellows and all adhered to the premise to cover the full extent of the lesion with the stent. Edge dissections were always stented. A minority of our patients had direct stenting performed and debulking techniques were not utilized in these patients. After the index percutaneous coronary intervention, patients may have presented with clinical symptoms to other facilities and thus would be excluded from this analysis. However, as we are the only interventional center in a large geographic area, most interventional patients return to our center for subsequent care. Quantitative coronary analysis was not utilized in our study, but all angiograms were reviewed by two observers, and a third observer was utilized if there were differences of opinion. Conclusions In-stent restenosis presents with various angiographic patterns. A substantial number of patients undergoing repeat angiography for recurrent symptoms following initial bare metal stent placement have lesions outside the stent. Patients who present early are more likely to have a stenosis at the stent edge. The occurrence of new lesions outside the stent may limit the effectiveness of stent-based effort to reduce restenosis. New strategies to limit restenosis outside the stent need to be explored. Acknowledgements. We wish to thank Walter J. Kroll for his excellent technical support, and acknowledge Scott A. Mulvey for his assistance in data collection.
1. Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med 1994;331:496–501. 2. Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994;331:489–495. 3. Laskey WK, Kimmel S, Krone RJ. Contemporary trends in coronary intervention: A report from the Registry of the Society for Cardiac Angiography and Interventions. Catheter Cardiovasc Interv 2000;49:19–22. 4. Holmes DR, Jr, Hirshfeld J Jr, Faxon D, et al. ACC expert consensus document on coronary artery stents. Document of the American College of Cardiology. J Am Coll Cardiol 1998;32:1471–1482. 5. Lowe HC, Oesterle SN, Khachigian LM. Coronary in-stent restenosis: Current status and future strategies. J Am Coll Cardiol 2002;39:183–193. 6. Ajani AE, Waksman R, Zimarino M, et al. Device selection in the treatment of in-stent restenosis with and without radiation (from the Gamma Radiation Trials). Am J Cardiol 2002;89:137–144. 7. Sousa JE, Costa MA, Abizaid A, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation 2001;103:192–195. 8. Moses JW, Leon MB, Popma JJ,et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315–1323. 9. Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221–231. 10. Lemos PA, Saia F, Ligthart JM, et al. Coronary restenosis after sirolimus-eluting stent implantation: Morphological description and mechanistic analysis from a consecutive series of cases. Circulation 2003;108:257–260. 11. Mehran R, Dangas G, Abizaid AS, et al. Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome. Circulation 1999;100:1872–1878. 12. Johansen O, Brekke M, Seljeflot I, et al. N-3 fatty acids do not prevent restenosis after coronary angioplasty: Results from the CART study. Coronary Angioplasty Restenosis Trial. J Am Coll Cardiol 1999;33:1619–1626. 13. Serruys PW, Foley DP, Jackson G, et al. A randomized placebo-controlled trial of fluvastatin for prevention of restenosis after successful coronary balloon angioplasty: Final results of the fluvastatin angiographic restenosis (FLARE) trial. Eur Heart J 1999;20:58–69. 14. Goldberg SL, Loussararian A, De Gregorio J, et al. Predictors of diffuse and aggressive intra-stent restenosis. J Am Coll Cardiol 2001;37:1019–1025. 15. Elezi S, Kastrati A, Pache J, et al. Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement. J Am Coll Cardiol 1998;32:1866–1873. 16. Baim DS, Levine MJ, Leon MB, et al. Management of restenosis within the Palmaz-Schatz coronary stent (the U.S. multicenter experience). The U.S. Palmaz-Schatz Stent Investigators. Am J Cardiol 1993;71:364–366. 17. Bossi I, Klersy C, Black AJ, et al. In-stent restenosis: Long-term outcome and predictors of subsequent target lesion revascularization after repeat balloon angioplasty. J Am Coll Cardiol 2000;35:1569–1576. 18. Hamburger JN, Foley DP, de Feyter PJ, et al. Six-month outcome after excimer laser coronary angioplasty for diffuse in-stent restenosis in native coronary arteries. Am J Cardiol 2000;86:390–394. 19. vom Dahl J, Dietz U, Haager PK, et al. Rotational atherectomy does not reduce recurrent in-stent restenosis: Results of the angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis trial (ARTIST). Circulation 2002;105:583–588. 20. Ajani AE, Waksman R, Cha DH, et al. The impact of lesion length and reference vessel diameter on angiographic restenosis and target vessel revascularization in treating in-stent restenosis with radiation. J Am Coll Cardiol 2002;39:1290–1296. 21. Gruberg L, Waksman R, Ajani AE, et al. The effect of intracoronary radiation for the treatment of recurrent in-stent restenosis in patients with diabetes mellitus. J Am Coll Cardiol 2002;39:1930–1936. 22. Popma JJ, Suntharalingam M, Lansky AJ, et al. Randomized trial of 90Sr/90Y beta-radiation versus placebo control for treatment of in-stent restenosis. Circulation 2002;106:1090–1096. 23. Waksman R, Cheneau E, Ajani AE, et al. Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies. Circulation 2003;107:1744–1749. 24. Kuchulakanti P, Lew R, Waksman R. Mechanisms and methods to resolve edge effect. J Invasive Cardiol 2003;15:363–366. 25. Miketic S, Carlsson J, Tebbe U. Influence of gradually increased slow balloon inflation on restenosis after coronary angioplasty. Am Heart J 1998;135:709–713. 26. Schweiger MJ, Garb JL, Blank F, et al. Long-term follow-up and influence of symptom-free interval on restenosis after repeat percutaneous transluminal coronary angioplasty. Am J Cardiol 1988;62:476–478. 27. Thury A, Wentzel JJ, Vinke RV, et al. Images in cardiovascular medicine. Focal in-stent restenosis near step-up: Roles of low and oscillating shear stress? Circulation 2002;105:e185–e187. 28. Mauri L, O'Malley AJ, Popma JJ, et al. Comparison of thrombosis and restenosis risk from stent length of sirolimus-eluting stents versus bare metal stents. Am J Cardiol 2005;95:1140–1145. 29. Schofer J, Schluter M, Gershlick AH, et al. G. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: Double-blind, randomised controlled trial (E-SIRIUS). Lancet 2003;362:1093–1099. 30. Mintz GS, Popma JJ, Pichard AD, et al. Limitations of angiography in the assessment of plaque distribution in coronary artery disease: A systematic study of target lesion eccentricity in 1446 lesions. Circulation 1996;93:924–931.

Advertisement

Advertisement

Advertisement