Skip to main content

ADVERTISEMENT

Restenosis

Clinical Images
11/28/2023
A 79-year-old male with effort angina was admitted to receive optical coherence tomography-guided percutaneous coronary intervention for restenosis of an everolimus-eluting stent implanted to the left anterior descending artery 8 years ago.
A 79-year-old male with effort angina was admitted to receive optical coherence tomography-guided percutaneous coronary intervention for restenosis of an everolimus-eluting stent implanted to the left anterior descending artery 8 years ago.
A 79-year-old male with effort...
11/28/2023
Journal of Invasive Cardiology
Original Contribution
03/01/2023
This database analysis of a single-center, high-volume tertiary institution examines preprocedural risk factors of mitral valve restenosis in patients submitted to percutaneous mitral balloon commissurotomy for mitral stenosis.
This database analysis of a single-center, high-volume tertiary institution examines preprocedural risk factors of mitral valve restenosis in patients submitted to percutaneous mitral balloon commissurotomy for mitral stenosis.
This database analysis of a...
03/01/2023
Journal of Invasive Cardiology
Original Contribution
05/11/2022
The Auryon 355-nm laser atherectomy system (AngioDynamics, Inc) showed a low rate of target-lesion revascularization (TLR) at 6-month follow-up in the investigational device exemption study. At present, real-world data are not available. The...
The Auryon 355-nm laser atherectomy system (AngioDynamics, Inc) showed a low rate of target-lesion revascularization (TLR) at 6-month follow-up in the investigational device exemption study. At present, real-world data are not available. The...
The Auryon 355-nm laser...
05/11/2022
Journal of Invasive Cardiology
10/14/2019
A meta-analysis of trials in endovascular therapy suggested an increased mortality associated with treatment exposure to paclitaxel. We analyzed how this controversy impacted device purchasing and related utilization patterns in the period...
A meta-analysis of trials in endovascular therapy suggested an increased mortality associated with treatment exposure to paclitaxel. We analyzed how this controversy impacted device purchasing and related utilization patterns in the period...
A meta-analysis of trials in...
10/14/2019
Journal of Invasive Cardiology
Clinical Images
09/26/2018
We present a patient with non-obstructive intraluminal clot protrusion treated with medical therapy. Follow-up OCT scan showed layered neointimal changes similar to images observed in stent failure.
We present a patient with non-obstructive intraluminal clot protrusion treated with medical therapy. Follow-up OCT scan showed layered neointimal changes similar to images observed in stent failure.
We present a patient with...
09/26/2018
Journal of Invasive Cardiology
Original Contribution
10/23/2017
Under-expanded and under-deployed stents carry a high risk of restenosis and thrombosis, with inherent serious clinical complications. We performed a retrospective analysis of prospectively collected data on all under-expanded, under-deployed...
Under-expanded and under-deployed stents carry a high risk of restenosis and thrombosis, with inherent serious clinical complications. We performed a retrospective analysis of prospectively collected data on all under-expanded, under-deployed...
Under-expanded and...
10/23/2017
Journal of Invasive Cardiology
Original Contribution
09/15/2017
Movement of the stent delivery system may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac...
Movement of the stent delivery system may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac...
Movement of the stent delivery...
09/15/2017
Journal of Invasive Cardiology
Original Contribution
06/30/2016
A review of paclitaxel-coated balloons as an emerging therapeutic option for the invasive management of infrainguinal peripheral artery disease. 
A review of paclitaxel-coated balloons as an emerging therapeutic option for the invasive management of infrainguinal peripheral artery disease. 
A review of paclitaxel-coated...
06/30/2016
Journal of Invasive Cardiology
Original Research
12/30/2015
Stent fractures in the SFA play a modest role in the development of in-stent restenosis. In this study, a majority of patients with in-stent restenosis did not have stent fracture.
Stent fractures in the SFA play a modest role in the development of in-stent restenosis. In this study, a majority of patients with in-stent restenosis did not have stent fracture.
Stent fractures in the SFA play...
12/30/2015
Vascular Disease Management
Clinical Editor's Corner
12/30/2015
Despite new technologies and research, stent fracture continues to be a challenge faced by vascular specialists. 
Despite new technologies and research, stent fracture continues to be a challenge faced by vascular specialists. 
Despite new technologies and...
12/30/2015
Vascular Disease Management