Skip to main content

Rotational atherectomy

11/25/2019
The aim of this review is to analyze the components and the use of the Rotablator System (Boston Scientific) and to better understand helpful tips and tricks in order to face the most common complications occurring during the procedure.
The aim of this review is to analyze the components and the use of the Rotablator System (Boston Scientific) and to better understand helpful tips and tricks in order to face the most common complications occurring during the procedure.
The aim of this review is to...
11/25/2019
Journal of Invasive Cardiology
10/29/2019
We report a case of RA-induced fistula between the diagonal branch and the accompanying vein. Thus far, the patient has had no relevant symptoms; thus, no intervention has been undertaken. We will closely monitor the patient to determine...
We report a case of RA-induced fistula between the diagonal branch and the accompanying vein. Thus far, the patient has had no relevant symptoms; thus, no intervention has been undertaken. We will closely monitor the patient to determine...
We report a case of RA-induced...
10/29/2019
Journal of Invasive Cardiology
Case Report
10/03/2017
We present the case of a man who presented with an inferior STEMI that required RA for successful intervention of a heavily calcified right coronary artery (RCA).
We present the case of a man who presented with an inferior STEMI that required RA for successful intervention of a heavily calcified right coronary artery (RCA).
We present the case of a man who...
10/03/2017
Cath Lab Digest
Case Report
04/30/2017
The Rotablator preferentially ablates hard, inelastic material, such as calcified plaque, that is less able to stretch away from the advancing burr than is healthy arterial wall (differential cutting). 
The Rotablator preferentially ablates hard, inelastic material, such as calcified plaque, that is less able to stretch away from the advancing burr than is healthy arterial wall (differential cutting). 
The Rotablator preferentially...
04/30/2017
Cath Lab Digest
Ask the Expert
09/05/2016
In this second article in the series, we will present cases illustrating the clinical applications of each device followed by a brief discussion.
In this second article in the series, we will present cases illustrating the clinical applications of each device followed by a brief discussion.
In this second article in the...
09/05/2016
Cath Lab Digest
Clinical Images
08/31/2016
A patient was found to have in-stent restenosis within three layers of underexpanded stents implanted in 2004, 2011, and 2014. Rotational atherectomy safely yielded stent strut ablation (reduced to one layer), lesion expansion, and very good...
A patient was found to have in-stent restenosis within three layers of underexpanded stents implanted in 2004, 2011, and 2014. Rotational atherectomy safely yielded stent strut ablation (reduced to one layer), lesion expansion, and very good...
A patient was found to have...
08/31/2016
Journal of Invasive Cardiology
Original Contribution
06/15/2016
We assessed the feasibility and safety of a rota-flush solution with 10,000 U of unfractionated heparin in 1 L of normal saline in rotational atherectomy patients as an alternative to the routinely used solution, which includes the RotaGlide...
We assessed the feasibility and safety of a rota-flush solution with 10,000 U of unfractionated heparin in 1 L of normal saline in rotational atherectomy patients as an alternative to the routinely used solution, which includes the RotaGlide...
We assessed the feasibility and...
06/15/2016
Journal of Invasive Cardiology
Original Contribution
04/30/2016
The “single-operator” technique allows successful RA without a skilled assistant to maintain wire position during advancement of the burr; the absence of an assistant should therefore not eliminate the performance of RA.
The “single-operator” technique allows successful RA without a skilled assistant to maintain wire position during advancement of the burr; the absence of an assistant should therefore not eliminate the performance of RA.
The “single-operator” technique...
04/30/2016
Journal of Invasive Cardiology
Case Management
03/03/2016
An entrapped rotational atherectomy burr is uncommon, but one of the nightmare complications in the cardiac cath lab, warranting the need for familiarity with various retrieval techniques and skilled application.
An entrapped rotational atherectomy burr is uncommon, but one of the nightmare complications in the cardiac cath lab, warranting the need for familiarity with various retrieval techniques and skilled application.
An entrapped rotational...
03/03/2016
Cath Lab Digest
09/08/2014
A case is presented that shows rotational atherectomy can be a useful tool in a compromising situation, such as severely underexpanded implanted stents.
A case is presented that shows rotational atherectomy can be a useful tool in a compromising situation, such as severely underexpanded implanted stents.
A case is presented that shows...
09/08/2014
Journal of Invasive Cardiology