Skip to main content

Emmanouil S. Brilakis, MD, PhD, FACC, FAHA, FESC, FSCAI

Invasive Thoughts
08/30/2012
I frequently visit various cardiac catheterization laboratories both in the US and abroad and watch live cases at various interventional meetings. I find such experiences invaluable for “opening the mind” to new, different, and often better...
I frequently visit various cardiac catheterization laboratories both in the US and abroad and watch live cases at various interventional meetings. I find such experiences invaluable for “opening the mind” to new, different, and often better...
I frequently visit various...
08/30/2012
Journal of Invasive Cardiology
Original Contribution
10/15/2017
We sought to examine contemporary perspectives and practices on chronic total occlusion percutaneous coronary intervention. An online questionnaire was created and distributed to cardiologists within the United States and internationally.
We sought to examine contemporary perspectives and practices on chronic total occlusion percutaneous coronary intervention. An online questionnaire was created and distributed to cardiologists within the United States and internationally.
We sought to examine...
10/15/2017
Journal of Invasive Cardiology
Original Contribution
04/26/2012
Abstract: Background. Device loss and entrapment are infrequent but potentially grave complications of percutaneous coronary interventions (PCI). There are limited contemporary data on the frequency, treatment, and consequences of these...
Abstract: Background. Device loss and entrapment are infrequent but potentially grave complications of percutaneous coronary interventions (PCI). There are limited contemporary data on the frequency, treatment, and consequences of these...
Abstract: Background. Device...
04/26/2012
Journal of Invasive Cardiology
Clinical Images
07/02/2012
Abstract: The GuideLiner catheter is an easy-to-use guide catheter extension that can facilitate vessel engagement and equipment delivery. We present two cases that illustrate two potential challenges associated with use of the GuideLiner...
Abstract: The GuideLiner catheter is an easy-to-use guide catheter extension that can facilitate vessel engagement and equipment delivery. We present two cases that illustrate two potential challenges associated with use of the GuideLiner...
Abstract: The GuideLiner...
07/02/2012
Journal of Invasive Cardiology
Original Contribution
09/15/2015
The impact of contrast type on coronary imaging using optical coherence tomography (OCT) has received limited study. We compared OCT imaging obtained using the non-ionic, iso-osmolar iodixanol with the ionic, low-osmolar ioxaglate. 
The impact of contrast type on coronary imaging using optical coherence tomography (OCT) has received limited study. We compared OCT imaging obtained using the non-ionic, iso-osmolar iodixanol with the ionic, low-osmolar ioxaglate. 
The impact of contrast type on...
09/15/2015
Journal of Invasive Cardiology
Clinical Images
04/25/2017
A 62-year-old man was referred for percutaneous coronary intervention of a severe circumflex lesion. The guidewire became entangled in the previously implanted left anterior descending artery stent. Caution should be used when wiring through...
A 62-year-old man was referred for percutaneous coronary intervention of a severe circumflex lesion. The guidewire became entangled in the previously implanted left anterior descending artery stent. Caution should be used when wiring through...
A 62-year-old man was referred...
04/25/2017
Journal of Invasive Cardiology
Original Contribution
01/12/2024
Data from the Manufacturer and User Facility Device Experience (MAUDE) database between 2012 and 2022 were used to investigate the most common modes of failure and related adverse events with the use of guide catheter extensions.
Data from the Manufacturer and User Facility Device Experience (MAUDE) database between 2012 and 2022 were used to investigate the most common modes of failure and related adverse events with the use of guide catheter extensions.
Data from the Manufacturer and...
01/12/2024
Journal of Invasive Cardiology
Brief Contribution
12/01/2021
Currently only the peripheral intravascular lithotripsy device is approved for use in the United States. We queried the United States FDA MAUDE database from January 1, 2016 to December 14, 2020 for all reports of adverse events and modes of...
Currently only the peripheral intravascular lithotripsy device is approved for use in the United States. We queried the United States FDA MAUDE database from January 1, 2016 to December 14, 2020 for all reports of adverse events and modes of...
Currently only the peripheral...
12/01/2021
Journal of Invasive Cardiology
Review
08/17/2009
ABSTRACT: Stenting of saphenous vein graft (SVG) lesions is associated with a high risk of periprocedural myocardial infarction, due primarily to distal embolization. Although embolic protection devices are the only clinical trial-proven...
ABSTRACT: Stenting of saphenous vein graft (SVG) lesions is associated with a high risk of periprocedural myocardial infarction, due primarily to distal embolization. Although embolic protection devices are the only clinical trial-proven...
ABSTRACT: Stenting of saphenous...
08/17/2009
Journal of Invasive Cardiology