Invia® NPWT Foam Dressing Kits

Invia Motion® Negative Pressure Wound Therapy System is for treating a variety of NPWT wounds in the acute, extended and home care settings. Available in three different settings (15-day, 60-day and Endure 3 years).

Visit Product Website

Medela, LLC

Medela, LLC

Medela provides an innovative portfolio of products and services for negative pressure wound therapy that includes devices, gauze and foam dressing kits, Invia® Silverlon® dressings, and accessories.

877-735-1626
815-307-8942

Available through durable medical equipment (DME) providers and direct to hospitals through Medela USA.

Yes
Yes
Yes

• Invia® devices have double-lumen technology, which provides Intelligent Pressure Control and Dynamic Exudate Removal technology
• Intelligent Pressure Control technology delivers the set pressure at the wound bed
• Dynamic Exudate Removal technology actively helps prevent blockages
• Provides NPWT across the continuum of care—from hospital to home
• Clear user interface supported by four buttons and a digital display
• Discreet carrying case, battery autonomy of 10 hours and compact design for comfort and mobility
• Preset pressure settings from -40mmHg to -175mmHg (-125mmHg default setting)
• Easy and secure tubing attachment with the quick-connector
• Choice of therapy run times to meet clinical needs (15-day, 60-day, Endure 3 years)
• Delivers the convenience of a personal pump while offering clinical flexibility with a choice of pressure settings, therapy modes and compatibility with both foam and gauze dressings
• Appropriate for use in all patient care settings
• Small blockages in the tubing are resolved by the pump
• Clinicians and patients are notified of any unresolved blockages

The Invia NPWT Systems contain a double-lumen with patented, electronically controlled feedback technology, Intelligent Pressure Control and Dynamic Exudate Removal, to ensure the prescribed pressure is delivered at the wound bed while dynamically adjusting airflow cycles to adapt to fluid fluctuations (up to 20 times per 5 mins), more accurately and efficiently removing fluid and innovating the standard of care.

The Invia Motion® Negative Pressure Wound Therapy System is indicated for use on diabetic neuropathic ulcers, pressure injuries, venous insufficiency ulcers, chronic wounds, traumatic wounds, acute or subacute wounds, dehisced wounds, partial-thickness burns, flaps and grafts.

Contraindicated for use in the presence of malignancy of the wound, untreated osteomyelitis, non-enteric fistula, unexplored fistula, necrotic tissue with eschar present, exposed vasculature, exposed nerves, exposed anastomotic site of blood vessels or bypass or exposed organs.

Refer to Instructions for Use (IFU).

Store Starter Kit between 15% and 93% humidity and -20° to 50°C (-4° to 122°F).

Refer to Instructions for Use (IFU).