Clinical and Angiographic Safety and Efficacy Trial with a New
Coronary Stent: The RESTOR Study of the R Stent

Peter den Heijer,* MD, PhD, Benno J.W.M. Rensing,§ MD, PhD, David P. Foley,? MD, PhD, Arjan A. van den Bos,* MD, Huub M.A. Corbeij,* MD, Michael A. Quarles van Ufford,* MD, Johannes A.M. te Riele,* MD, Paul C.H. Rooset,* MD, Patrick W. Serruys,? MD, PhD
August 2004
Over the last decade, coronary stent implantation has gradually become the choice treatment of choice in percutaneous coronary intervention (PCI).1,2 The enhanced safety of coronary interventions, the lower complication rate, the better immediate angiographic and functional results and especially the lower restenosis rate compared to balloon angioplasty have won the battle with other interventional treatment modalities in all but a few types of lesions.3–9 Today, a huge number of different models and makes of coronary stents are available. In the early years of the 21st century all attention is focused on the new development of drug eluting stents, promising the ultimate solution of the restenosis problem.10,11 An argument could exist that the mechanical properties of drug-eluting stents become increasingly important as indications shift towards more complex and multivessel PCIs. A new stent design therefore has to offer optimal radial strength, vessel conformability, side branch access, and a high flexibility and low profile for ease of delivery. Moreover, new stents still have to be evaluated with proven clinical and angiographic scientific study methods before they can safely be further developed into drug carrying and eluting platforms. The RESTOR trial (R Stent Efficacy and Safety Trial by Orbus) was undertaken to evaluate the safety and efficacy of a novel stent design, the R stent, by measuring Major Adverse Cardiac Events (MACE) at 210 days post implantation and by assessing quantitative coronary angiography (QCA) results at 6 months follow-up. Methods Patients. Between May and December 2000 a total number of 121 patients (mean age 58.8 years, range 32–79 years, 75% male and 25% female) were included in 2 Dutch centers: the Amphia Hospital Breda and the Thoraxcenter Rotterdam. Their baseline demographic and angiographic characteristics are shown in Table 1. Patients with symptomatic stable or unstable angina pectoris or documented silent ischemia and a significant single, de novo coronary lesion of a length up to 25 mm and a reference diameter between 2.75 and 4.0 mm could be included in this trial. Patients with a total occlusion, unprotected left main stem disease, large intracoronary thrombus, acute myocardial infarction, an ejection fraction below 30%, and known allergies to aspirin, clopidogrel, heparin or stainless steel were excluded. The study protocol was approved by the local ethics committees and written, informed consent was obtained in all cases. Stent design. The R Stent (Orbus Medical Technologies, Ft. Lauderdale, Florida) is a balloon expandable device fashioned from 316LVM stainless steel tubing. The patented dual helix design of the R Stent is unique. It provides more flexibility than regular slotted tube configurations yet maintains high radial strength which is a weakness of coil wire designs. The strut thickness of the R Stent results in moderate radiopacity without obscuring the lesion area. The cell geometry allows for easy side branch access and dilatation of side branch orifices up to 4.5 mm without distortion of the opposite stent wall. The R Stent is pre-mounted on a low-profile rapid exchange PTCA catheter. Stent implantation. All PCI procedures were carried out through femoral artery access and 6 French guiding catheters. The R stents were implanted after predilatation with adequately sized balloon catheters. Additional stents were implanted in cases of suboptimal results or edge dissections in adjacent segments. All patients received an oral loading dose of 300 mg clopidogrel and 5000–10000 units of intravenous heparin before the procedure, and were subsequently treated with ASA 80–300 mg. and clopidogrel 75 mg daily. Glycoprotein IIb/IIIa inhibitors were administered if considered necessary by the operator. Quantitative coronary angiography. Coronary angiography was performed before and after PCI and at 6 months follow-up in multiple views after intracoronary administration of nitrates. Quantitative analysis with standardized edge detection techniques using the CAAS II system (Pie Medical, Maastricht, the Netherlands) was performed at the independent core laboratory (Cardialysis, Rotterdam, the Netherlands). Restenosis was defined as a stenosis of 50% or more at the follow-up angiogram. Late luminal loss was defined as the difference between the minimal luminal diameter (MLD) after the procedure and at 6 months. Endpoints and definitions. The primary endpoint of the study was the incidence of major adverse cardiac events (MACE) at 210 days post-procedure. MACE were defined as cardiac death, MI (Q-wave and non-Q wave, CK levels > 2 times normal), CABG and TLR. The secondary endpoints were MACE at 30 days post-procedure, major bleeding and vascular complications, and angiographic parameters (percentage diameter stenosis, minimal luminal diameter and restenosis rate) by means of central core laboratory analysis. Angiographic success was defined as a diameter stenosis post-procedure of Statistical methods. The statistical and safety analysis were performed according to the intention-to-treat principle. Statistical significance testing was not performed because this was an observational, non-randomized study. Descriptive statistics were performed for all relevant variables. For categorized variables the data were collected as counts and incidence rates, for continuous variables as mean, standard deviation, median, minimum and maximum. The occurrences of major clinical events and target lesion revascularization were analyzed using the actuarial life table method. Results Acute results. The diameters and lengths of the R Stents used in this study are shown in Table 2. A single study stent was implanted in 102/121 patients (84.3%), 2 study stents in 16/121 patients (13.2%), and 3 study stents in 1 patient (0.8%). In one patient (0.8%) a non-study stent was implanted as well as a study stent because of non-availability of the appropriate size of the study stent at that moment. There was 1 case of emergency CABG because of guidewire-induced spiral dissection in a severely diseased RCA before stent implantation could be attempted. Thus, the angiographic success rate of R Stent implantation, defined as 50% diameter stenosis at angiographic follow-up was 20.8% (21/101 patients). Figure 4 shows the cumulative distribution of diameter stenosis pre- and post-PCI and at follow-up angiography. With numerous new coronary stents becoming available on the market the attention of investigators in this field is shifting towards coating these stents with antiproliferative and other drugs. It is in our opinion however still mandatory to investigate the safety and efficacy of a new design on its mechanical, clinical and angiographic merits using a well established prospective study method and core lab. This is especially true if such a stent will be further developed as a carrier of such drugs in the near future. The RESTOR trial demonstrates that the R Stent as a bare, non-coated stent, is a safe and effective device. It is associated with a high primary success rate and a MACE rate comparable to other modern stainless steel coronary stents.7,12–16 The binary restenosis rate of 20.8% found in this trial is in the expected range for a study with an average stented length of treated segments of 15.7 mm per patient, using more than 1 stent in 19/121 patients (15.7%) (Table 2).17,18 The R Stent has special mechanical properties because of its unique dual helix design. The resulting flexibility can be seen from Figure 4: A single R Stent was implanted easily in a study patient with an extremely tortuous RCA. Other potential advantages such as the suitability of the R Stent for direct stenting and sidebranch/bifurcation treatment will be addressed in future, more specific studies. Conclusions The R Stent is a new coronary stent with a dual helix design, which offers the flexibility, conformability and sidebranch access of a coil stent in combination with the radial strength and scaffolding properties of a tubular stent. The RESTOR study has established its safety and efficacy in an open, prospective clinical endpoint and quantitative angiography trial. Its angiographic restenosis rate lies within the expected range for a bare, non-coated stent. The R Stent is well suited as a platform for the further development of drug-eluting stents. Acknowledgement. The authors wish to acknowledge the helpful support of Cardialysis, Rotterdam, the Netherlands, for their data and manuscript review.
1. Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. New Engl J Med 1994;331:496–501. 2. Serruys PW, De Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease. New Engl J Med 1994;331:489–495. 3. Betriu A, Masotti M, Serra A, et al. Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START): A four-year follow-up. J Am Coll Cardiol 1999;34:1498–1506. 4. Buller CE, Dzavik V, Carere RG, et al. Primary stenting versus balloon angioplasty in occluded coronary arteries: The Total Occlusion Study of Canada (TOSCA). Circulation 1999;100:236–242. 5. Weaver WD, Reisman MA, Griffin JJ, et al. Optimum percutaneous transluminal coronary angioplasty compared with routine stent strategy trial (OPUS-1): A randomised trial. Lancet 2000;355:2199–2203. 6. Versaci F, Gaspardone A, Tomai F, et al. A Comparison of Coronary artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery. N Engl J Med 1997;336:817–822. 7. Serruys PW, Van Hout B, Bonnier H, et al. Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II). Lancet 1998;352:673–681. 8. Park SW, Lee CW, Hong MK, et al. Randomized comparison of coronary stenting with optimal balloon angioplasty for treatment of lesions in small coronary arteries. Eur Heart J 2000;21:1785–1789. 9. Serruys PW, Foley DP, Suttorp MJ, et al. A randomized comparison of the value of additional stenting after optimal balloon angioplasty for long coronary lesions: Final results of the additional value of NIR stents for treatment of long coronary lesions (ADVANCE) study. J Am Coll Cardiol 2002;39:393–399. 10. Morice MC, Serruys PW, Sousa JE, et al. A Randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773–1780. 11. Teirstein PS. Living the dream of no restenosis (Editorial). Circulation 2001;104:1996–1998. 12. Kastrati A, Schomig A, Dirschinger J, et al. Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease. Circulation 2000;101:2478–2483. 13. Kastrati A, Mehilli J, Dirschinger J, et al. Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 2001;103:2816–2821. 14. Lansky AJ, Roubin GS, O’Shaughnessy CD, et al. Randomized comparison of GR-II stent and Palmaz-Schatz stent for elective treatment of coronary stenoses. Circulation 2000:1364–1368. 15. Miketic S, Carlsson J, Tebbe U. Randomized comparison of J&J Crown stent versus NIR stent after routine coronary angioplasty. Am Heart J 2001;142(5):E8. 16. Wohrle J, Al-Khayer E, Grotzinger U, et al. Comparison of the heparin-coated vs. the uncoated Jostent — No influence on restenosis or clinical outcome. Eur Heart J 2001;22:1808–1816. 17. Kastrati A, Schömig A, Elezi S, et al. Predictive factors of restenosis after coronary stent placement. J Am Coll Cardiol 1997;30:1428–1436. 18. Serruys PW, Kay IP, Disco C, et al. Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months. Results of a meta-analysis of the Belgian Netherlands Stent Study (BENESTENT) I, BENESTENT II Pilot, BENESTENT II and MUSIC Trials. J Am Coll Cardiol 1999;34:1067–1074.

Advertisement

Advertisement

Advertisement