PCR London Valves Meeting: Late-Breaking Post-Market Study Data Reinforce Clinical Procedural Success and Safety of the ACURATE neo2™ Aortic Valve System

MARLBOROUGH, Mass., Nov. 28, 2022 -- Boston Scientific Corporation announced the first results from the ACURATE neo2 Post Market Clinical Follow-up (PMCF) study evaluating the performance of the ACURATE neo2 Aortic Valve System. The findings, which included a high procedural success rate of 98.4% and low rates of mortality and paravalvular leak (PVL), were presented during a late-breaking clinical trial session at PCR London Valves 2022 and published simultaneously in EuroIntervention.

In this European study, the primary safety endpoint of all-cause mortality was 0.8% at 30 days. The data also demonstrated that no patients experienced greater than moderate PVL, 1.9% experienced moderate PVL and 18.9% experienced mild PVL. Other notable findings from the study included a low 6.5% rate of new pacemaker implantation 30 days post procedure, with no incidence of disabling stroke or acute kidney injury.

 

ACURATE neo2™ Aortic Valve System.
ACURATE neo2™ Aortic Valve System.

 

"With this foundational data set, we now have post-market surveillance results that validate the use of the current-generation ACURATE neo2 valve for the management of patients with severe aortic stenosis," said Dr. Lars Søndergaard, professor of cardiology, DMSc, FESC, Department of Cardiology, Rigshospitalet and study co-principal investigator. "The data suggest that the annular sealing technology minimizes leakage around the valve – providing greater improvement in PVL than observed with the prior-generation ACURATE neo valve – all while maintaining single-digit permanent pacemaker rates, which contributes to better long-term patient outcomes."

The single-arm, prospective ACURATE neo2 PMCF study includes 250 patients with severe aortic stenosis from 18 European centers and will evaluate outcomes for five years following the procedure. It also includes a primary imaging endpoint to assess the visually apparent thickening of the prosthetic valve leaflets (HALT), a phenomenon with theoretical potential effects on valve durability or thrombotic complications. The reported HALT rate of 24.5% at 30 days post procedure falls within the range presented in previous TAVR trials with competitive devices.

"These trial data confirm the success of meaningful and differentiated enhancements included in the design of the ACURATE neo2 valve, from low rates of PVL and first-time pacemaker implantation to excellent hemodynamic performance and high rates of procedural success and safety," said Dr. Ian Meredith, global chief medical officer, Boston Scientific. "We look forward to reviewing longer-term results from this trial and bringing this differentiated TAVR technology to more patients and their physicians."

The ACURATE neo2 Aortic Valve System received CE Mark in 2020 and is being evaluated in the currently enrolling ACURATE IDE trial in the U.S. and Canada.

To learn more, visit www.bostonscientific.com.eu/acurateneo2.

*In the U.S., the ACURATE neo2TM Aortic Valve System is an investigational device and not available for sale.
** Dr. Søndergaard has not been compensated by Boston Scientific Corporation for his work on the ACURATE neo2 PMCF study or his quote within this news release.

About Boston Scientific
Boston Scientific transforms lives through innovative medical solutions that improve the health of patients around the world. As a global medical technology leader for more than 40 years, we advance science for life by providing a broad range of high performance solutions that address unmet patient needs and reduce the cost of healthcare. For more information, visit www.bostonscientific.com and connect on Twitter and Facebook.